Low voltage peak control connections, Low voltage outdoor sensor connections, Low voltage room thermostat connections – Steffes 4140 Simplified Installation Guide User Manual

Page 4: We y 1 y 2, Cblower speed a b, Single stage heat pump application, Two stage heat pump application, D6 rly1, D4 fid 2, D1 j4

Advertising
background image

The W/E Jumper must be installed

Air

To Control Board

D4

Fid 2

Blower

C3

R1

R2

P10

D6

RLY1

P11

D5 D7 D3

Wa

te

r

W

E

Y

1

Y

2

P5

J3

J2

J1

D2

J4

D1

P6

P4

C

B

A

D

Speed

Blower

J6

J5

P3

P2

P8

P9

Air Conditioner

Connections

(If being used in the

application)

The Y1/Y2 Jumper must be installed

Y

W

G

C

TH5110D

Honeywell

R

c

R

Y

Outdo

o

r

W/

Y1

AUX

G

O

Y2

Y1

R C

H/E

2

O

2

2

Y2

COM

Outdo

o

r

NO

AP

P

RP

NC

Aux.

Peak

Inputs

Relay

C

P1

To Control Board

Comfort Plus

R

C

LV Circuit Board

P7

9

LOW VOLTAGE PEAK

CONTROL CONNECTIONS

If utilizing a Steffes Time Clock

Module or Power Line Carrier control,

refer to the installation instructions

provided with the device.

10

LOW VOLTAGE OUTDOOR SENSOR

CONNECTIONS

1. Route low voltage wire from load

control device to terminal block.

2. Connect field wiring to “RP” and “P”

positions.

The outdoor temperature sensor can be installed by wiring it directly to the

system or to the Steffes power line carrier (PLC) system.
Direct Wired:

1. Mount outdoor sensor in a location where it can accurately sense

outdoor temperature.

2. Route low voltage wire from outdoor sensor to electrical

compartment:
•

Outdoor sensor wire MUST NOT be combined with other control

wiring in a multi-conductor cable.

•

Seal external wall openings.

•

Outdoor sensor lead can be extended to 250 ft.

•

Unshielded Class II (thermostat) wire can be used provided it is

segregated from any line voltage wiring.

3. Connect outdoor sensor wires to the two "OUTDOOR" positions of the

low voltage terminal block.

If connecting to the Steffes

power line carrier system,

follow the installation instruc-

tions in the PLC system’s

Owner’s and Installer’s Guide.

LOW VOLTAGE ROOM THERMOSTAT CONNECTIONS

A 24 VAC thermostat must be used (digital recommended).
1. Disconnect power to the Comfort Plus system.
2. Route low voltage wires from the thermostat to the

Comfort Plus System.

3. Insulate thermostat wire wall opening if necessary and

attach thermostat to the wall. When using a mechani-

cal thermostat or thermostat with anticipator, resistor

kit #1190015 must be installed to ensure proper

operation.

4. Connect low voltage wires from thermostat into

terminal block as shown.

11

12

SOFTWARE CONFIGURATION AND INSTALLERS FINAL CHECKOUT

To ensure proper operation, the system software must be configured for the application. Refer to the Configuration Menu in

the Owner's and Installer's Manual or to the Configuration Guide provided by your local power company. Also, complete the

Installer's Final Checkout Procedure found in the Owner's and Installer's Manual.

Part No. 1200283-6

3050 Hwy 22 North w Dickinson, ND 58601-9413 w www.steffes.com

NOTE: For detailed heat call information, reference the

Owner's and Installer's Manual.

P8

P9

Aux.

COM

NC

AP

NO

Relay

Outdoor Sensor

O

W/

Y1

AUX

Y2 G

Ou

td

o

o

r

Ou

td

o

o

r

Y2

R

H/E

2

Y1

C

O

2

2

RP P

R

C

P1

P11

D3

D7

D5

W

E

Y

1

Y

2

Water

Ai

r

P6

D1

P5

Blower

J3

J1

J2

J4

D2

To Control Board

P3

C

Blower
Speed
A

B

J5

J6

C3

D

P4

P2

Inputs

Peak

P7

LV Circuit Board

Comfort Plus

To Control Board

P10

Fid 2

RLY1

D4

D6

R2

R1

P9

Aux.

CO

M

NC

AP

NO

Relay

P8

O

W/

Y1

AUX

Y2 G

Out

door

Out

door

Y2

R

H/E

2

Y1

C

O

2

2

RP P

R

C

P1

Inputs

Peak

P7

LV Circuit Board

Comfort Plus

To Control Board

P10

Fid 2

RLY1

D4

D6

R2

R1

P11

D3

D7

D5

W

E

Y

1

Y

2

Water

Ai

r

P6

D1

P5

Blower

J3

J1

J2

J4

D2

To Control Board

P3

C

Blower
Speed

A

B

J5

J6

C3

D

P4

P2

Dry Contact Peak

Control Switch

Single Stage Heat Pump Application

IMPORTANT

A

B

C

D

W /

E

Y1

/

Y2

J1

J2

J3

J4

J5

J6

Blower

Speed

Stand Alone Furnace Application with Uncontrolled

Air Conditioning

IMPORTANT

A

B

C

D

W / E

Y1 /

Y

2

J1

J2

J3

J4

J5

J6

Blower

Speed

Two Stage Heat Pump Application

IMPORTANT

P8

Peak

Aux.

Inputs

Relay

The Y1/Y2 Jumper must be installed

Honeywell TH5220D

Aux

E

L

C

G O/B

R

Y

R

c

C - Low Voltage Common
R - Low Voltage Hot
O - Reversing Valve

Y - Compressor

To Heat Pump

Outdoor Sensor

The W/E Jumper must be installed

P9

H/E

R C

Ou

tdoo

r

Ou

tdoo

r

CO

M

NC

NO

W/

D6

RLY1

To Control Board

D4

Fid 2

Blower

To Control Board

Ai

r

C3

P10

R1

R2

P11

D5 D7 D3

Wa

te

r

Y

1

Y

2

W

E

D2

J3

J2

J1

P5

D1

J4

P6

P4

Speed

Blower

J6

J5

C

B

A

D

P2

P3

Y1

AUX

O

G

Y2

Y1

2

Y2

2

2

O

C

R

Comfort Plus

LV Circuit Board

P7

AP

P

RP

P1

Honeywell TH5320U

R

R

Y

C

O/B

G

Aux

Y2

Y2 - Compressor Stage 2
C - Low Voltage Common

c

L

R - Low Voltage Hot
O - Reversing Valve

To Heat Pump

Y1 - Compressor Stage 1

The Y1/Y2 Jumper must be removed

W/

NO

NC

CO

M

O

u

tdoor

O

u

tdoor

C

R

H/E

RLY1

D6

To Control Board

Fid 2

D4

Blower

To Control Board

O

D3

R2

R1

D7

D5

P11

W

E

Y

1

Y

2

Wat

e

r

J4

D1

ÁÂ

J1

J2

J3

P10

ÁÃ

D2

D

A

B

C

C3

J5

J6

Blower
Speed

P4

P3

AUX

Y2 G

Y1

O

2

2

Y2

Y1

Á

Ai

r

LV Circuit Board

Comfort Plus

ÁÄ

P1

P2

БЕ

В

БЖ

RP

2

AP

P

Aux.

Relay

Peak

Inputs

The W/E Jumper must be installed