DUCTING

4100 Series systems are factory configured for a left-to-right

or right-to-left airflow. For a down flow configuration, order

Down Flow Kit #1301578.

1. Unbox supply air blower plenum assembly.
2. Remove and discard metal plate securing supply air

blower to plenum assembly.

3. Attach plenum support bracket to supply air side using

blunt tip screws.

4. Attach supply blower wiring harness to blower. Place

excess wiring in base below radiant heat shield.

5. Verify blower is installed with motor facing away from

system.

6. Attach supply air blower plenum. Drill two 1/8" holes per

edge. Use self-tapping screws.

7. Connect return air and supply air ducting. The air holes

directly above the air outlet on the right side MUST be

contained in the duct system.

8. If necessary, adjust supply air blower speed by using the

chart below.

9. The W/E jumper MUST be in the ON position or the blower

will not operate with an E call from the thermostat.

•

When interfacing with a heat pump, the A-Coil MUST
be placed on the return air side.

••••• To maintain a room temperature of 85

o

F or less in

the mechanical room, a 24" x 24" opening can be

installed in the area or a 6" x 6" non-closing register

can be cut into the return air duct. Refer to Place-

ment and Clearance Requirements section of

Owner’s and Installer’s Manual for more information.

Supply Air Plenum Support Bracket

Radiant Heat Shield

Air

Holes

25

1

16

"

24

1
4

"

8 3/8"

(± 1/4")

22 5/8"

M

A

M

STE FFES

P
M

18" (

1
2

HP Blower)

22

1
2

" (1 HP Blower)

10

1
2

22

5

16

8

LINE VOLTAGE ELECTRICAL CONNECTIONS

LIN

E

2

LIN

E

1

LIN

E

2

LIN

E

1

CHARGE CIRCUIT #3

CHARGE CIRCUIT #2

CHARGE CIRCUIT #1

BLOWERS/CONTROLS CIRCUIT

CHARGE CIRCUIT #4

(MODEL 4130 and 4140 ONLY)

LIN

E

2

LIN

E

1

LIN

E

1

LIN

E

2

LIN

E

1

LIN

E

2

Comfort Plus

Circuit Breakers

To Servi

ce (B

rea

ker) Panel

CIRCUIT PHASING CONNECTIONS

HAZARDOUS VOLTAGE: Risk of electric shock. Can

cause injury or death. DO NOT operate the Comfort

Plus heating system without ducting installed to both

the air inlet and outlet.

• To ensure proper operation and safety,

all line voltage circuits must be segre-

gated from low voltage wiring.

• To reduce electromagnetic fields associ-

ated with electrical circuits and to avoid

induced voltage on sensors and elec-

tronic devices, the circuit phases MUST

be alternated as shown on the left.

• DO NOT install any wiring in the line

voltage compartment of the Comfort

Plus heating system unless it is rated for

line voltage.

WARNING

WARNING

WARNING

WARNING

WARNING

WARNING

WARNING

WARNING

WARNING

WARNING

Jumper

½ HP Variable

Speed CFM

1 HP Variable

Speed CFM

A 1000 1200
B 1200 1400

C 1400 1600
D 1600 2000

External static pressure should

not exceed .75” water column.

Model

Control Crct Chrg Crct #1 Chrg Crct #2 Chrg Crct #3 Chrg Crct #4

4120 - 14.0kW

7.00

21.88

21.88

14.58

N/A

4120 - 19.2kW

7.00

30.00

30.00

20.00

N/A

4120 - 24.8kW

7.00

38.75

38.75

25.83

N/A

4130 - 28.8kW

7.00

30.00

30.00

30.00

30.00

4130 - 37.2kW

7.00

38.75

38.75

38.75

38.75

4140 - 38.4kW

7.00

40.00

40.00

40.00

40.00

4140 - 45.6kW

7.00

47.50

47.50

47.50

47.50

Full Load Current

Show n for 240VAC only. Circuit deration not included.

HAZARDOUS VOLTAGE: Risk of electric shock. Can cause injury

or death. Do not energize the Comfort Plus heating system until

installation is complete.
1. Route all line voltage wires through knockout(s) and into electrical

panel.

2. Make proper field wiring connections phasing circuits as shown on

the left. Reference the Unit Identification Label for circuit information.