Convotherm pc-haccp – Cleveland Range Convotherm PC-Control User Manual

Page 6

Advertising
background image

Operating Instructions

2. CONVOTHERM PC-HACCP

page

3

10 July 2006

CONVOTHERM PC-HACCP

Select Temperature in ºC or ºF

1. In the CONVOTHERM-HACCP window, click Options.

2. Click Measurement unit.

3. Click °C or °F.

4. Click OK to confirm or Cancel to quit without making changes.

2.1.3 Setting the Network Address on the Combi Ovens
• Address 1 is factory set on all Combis.
• To connect more Combis to the PC, the Addresses must be changed to 2, 3, 4, etc.
• No change is needed to work with only one Combi.

On the Combi Control Panel:

1. Press the Smart Key.

2. Scroll to the Setup icon (it looks like an oven).

3. Press the Smart Key for YES.

4. Scroll to the Network Address icon (it looks like three computers tied together).

5. Enter the address of the Combi.

• The first Combi is 1, the second Combi is 2, etc.

6. Press the Stop key to end the program.

7. Switch the Combi OFF and then back ON.

2.1.4 Log On and Off Combis in CONVOTHERM PC-HACCP
• All Combis connected to the PC must be logged on to the CONVOTHERM PC-HACCP

software.

• Each Combi needs an individual network address (number) and a name.
• When the Combis are logged on, they are displayed on the screen with a symbol and a

name and change to a light color.

• The network address assigned during log on must match the address set on the Combi.
(Continued on next page.)