Name Cable

Color

Function

12VDC Brown/White

DC 12V (50mA maximum)

GND Blue/White GND
D+ Purple/White

RS485

data

+

D- Gray

RS485

data

-

DI Green/White

Digital

signal

input

DO Orange/White

Digital

signal

output

3. Factory Default Reset
This button is used to restore the all factory default settings. Sometimes restarting the
device will make the system back to a normal state. However, if the system still got
problems after restart, user can restore the factory default settings and install it again.

Restore the device:

(i) Press the button down continuously.
(ii) Hold the button at least 5 seconds and release it. Then the device has been

restored to default settings and reboot again.

Note:

Restoring the factory default setting will lose the all previous settings included IP

address forever. User needs to run the IPWizard II program to search the device and
configure it to let the device work properly again.


4. DC-in Jack
The input power is 12VDC. Note that supply the power to the Network Camera with the
power adapter included in package.

5. MIC in (audio in)
Connect a microphone to the network camera.


6. Line out (audio out)
Connect a loud speaker to the network camera. This function is for voice alerting and
two-way audio.