WL Series

3

Repeat on the opposite side.

3. When assembled, the tank must sit

level or slope slightly towards the
drain cock to allow the tank to
drain properly.

LOCATION

It is extremely important to install the
compressor in a clean, well ventilated area
where the surrounding air temperature
will not be more than 100°F.

A minimum clearance of 18 inches
between the compressor and a wall is
required because objects could
obstruct air flow.

Do not locate the
compressor air

inlet near steam, paint spray, sandblast
areas or any other source of
contamination. This debris will damage
the motor.

ELECTRICAL INSTALLATION

All wiring and
electrical

connections should be performed by a
qualified electrician. Installation must be
in accordance with local codes and
national electrical codes.

Never use an extension
cord with this product. Use
additional air hose instead
of an extension cord to
avoid power loss and permanent motor
damage. Use of an extension cord voids
the warranty.

GROUNDING INSTRUCTIONS

1. This product is for use on a nominal

120 volt circuit and has a grounding
plug that looks like the plug illustrated
in Fig. 3. Make sure the product is
connected to an outlet having the
same configuration as the plug. This
product must be grounded. In the
event of an electrical short circuit,
grounding reduces risk of electrical
shock by providing an escape wire for
electric current. This product is
equipped with a cord having a
grounding wire with an appropriate

!

CAUTION

!

WARNING

!

CAUTION

grounding plug. Plug must be plugged
into an outlet that is properly installed
and grounded in accordance with all
local codes and ordinances.

Improper use of grounding
plug can result in a
possible risk of electrical
shock!

Do not use a
grounding adapter

with this product!

2. If repair or replacement of cord or plug

is necessary, do not connect grounding
wire to either flat blade terminal. The
wire with insulation having an external
surface that is green (with or without
yellow stripes) is the grounding wire.

Never connect

green (or green and

yellow) wire to a live terminal.

3. Check with a qualified electrician or

serviceman if grounding instructions
are not completely understood, or if in
doubt as to whether product is
properly grounded. Do not modify
plug provided; if it will not fit outlet,
have proper outlet installed by a
qualified electrician.

WIRING

1. Local electrical wiring codes differ from

area to area. Source wiring, plug and
protector must be rated for at least the
amperage and voltage indicated on
motor nameplate, and meet all electrical
codes for this minimum.

2. Use a slow blow fuse or a circuit

breaker.

Overheating, short
circuiting and fire

damage will result from inadequate
wiring, etc.

NOTE: 120 volt, 15 amp units can be
operated on a 120 volt circuit under the
following conditions:

a. No other electrical appliances or lights

!

CAUTION

!

WARNING

!

DANGER

!

DANGER

are connected to the same branch
circuit.

b. Voltage supply is normal.

c. Circuit is equipped with a 15 amp

circuit breaker or a 15 amp slow blow
fuse.

3. If these conditions cannot be met or if

nuisance tripping of current
protection device occurs, it may be
necessary to operate compressor from
a 120 volt, 20 amp circuit.

Pressure Switch - Auto/Off Switch - In
the AUTO position, the compressor
shuts off automatically when tank
pressure reaches the maximum preset
pressure. In the OFF position, the
compressor will not operate. This
switch should be in the OFF position
when connecting or disconnecting the
power cord from the electrical outlet
or when changing air tools.

Regulator - The regulator controls the
amount of air pressure released at the
hose outlet.

ASME Safety Valve - This valve
automatically releases air if the tank
pressure exceeds the preset maximum.

Discharge Tube - This tube carries
compressed air from the pump to the
check valve. This tube becomes very
hot during use. To avoid the risk of
severe burns, never touch the
discharge tube.

Check Valve - A one-way valve that
allows air to enter the tank, but
prevents air in the tank from flowing
back into the compressor pump.

Handle - Designed to move the
compressor.

Never use the
handle on wheeled

units to lift the unit completely off the
ground.

Drain Petcock - This valve is located on
the bottom of the tank. Use this valve
to drain moisture from the tank daily
to reduce the risk of corrosion.

Reduce tank pressure below 10 PSI,
then drain moisture from tank daily to
avoid tank corrosion. Drain moisture

!

WARNING

TEST

RESET

Figure 3 - Grounding Method

STOP!

Grounding

Pin

Installation

Operation

Grounded Outlet

Assembly

(Con't)

22 Sp

Guía de diagnóstico de averías

Problema

Posible(s) Causa(s)

Acción a tomar

1. No hay energía eléctrica

2. Fusible quemado
3. Cortacircuito desconectado
4. Protector térmico desconectado
5. Presostato dañado
6. La válvula de chequeo está dañada

1. Voltaje bajo
2. Defecto de la bobina del motor
3. Válvula de chequeo o desfogue

defectuosa

1. Fusible inadecuado, circuito

sobrecargado

2. Válvula de chequeo o desfogue

defectuosa

1. Voltaje bajo
2. Filtro de aire está atascado
3. Poca ventilación/temperatura

ambiental muy alta

4. La válvula de chequeo está dañada

1. Hay alguna válvula con fugas, rota o

floja o el paso de aire está
restringido

2. El sistema de desfogue del presostato

está dañado

3. Los cojinetes del excentrico o eje del

motor están dañados

4. El cilindro o anillo del pistón está

desgastado o rayado

5. Pernos flojos, tanque desnivelado

1. ¿Está conectado? Chequée el fusible/cortacircuito o

protector de sobrecarga del motor

2. Reemplace el fusible quemado
3. Conéctelo, determine la causa del problema
4. Espere a que el motor se enfrie
5. Reemplácelo
6. Desconecte y reemplace la válvula de chequeo

Antes de desmantelar
la válvula de

chequeo purgue el aire del tanque

1. Chequée las conecciones, chequée con un voltimetro
2. Reemplace el motor
3. Reemplácela o repárela

Antes de desmantelar
la válvula de

chequeo purgue el aire del tanque

1. Cerciórese de que está usando el fusible adecuado,

use un fusible de acción retardada. Desconecte los
otros artefactos eléctricos del circuito o conecte el
compresor a otro circuito.

2. Reemplácela o repárela

Antes de desmantelar
la válvula de

chequeo purgue el aire del tanque

1. Chequée con un voltimetro
2. Limpie el filtro (vea la sección de Mantenimiento)
3. Mueva el compresor a un área bien ventilada

4. Reemplácela

Antes de desmantelar
la válvula de

chequeo purgue el aire del tanque

1. Reemplácela

2. Reemplácelo o repárelo según sea necesario

3. Reemplácelo

4. Reemplácelo o repárelo según sea necesario

5. Apriete los pernos, nivele el tanque con unas

almohadillas

!

PELIGRO

!

PELIGRO

!

PELIGRO

!

PELIGRO

El compressor no
funciona

El motor hace ruido
pero no funciona o
funciona lentamente

Los fusibles se
queman/cortacircuito se
activa con frecuencia

Nunca use jamás un
cordón de extensión
con este aparato

El protector de
sobrecarga térmica se
activa constantemente

Golpea, hace ruido,
vibración excesiva

Compresores Sin Aceite

!

PRECAUCION

www.chpower.com