Pro16 outputs, Pro64/pro16 channel mapping – Aviom ASI User Manual

Page 21

Advertising
background image

13

F

roNt

P

ANel

F

eAtures

In an all‑analog network, the sample rate can be set at the Control Master to

the following:

44.1kHz

48

kHz

88.2

kHz

96

kHz

176.4

kHz

192

kHz

When an external clock is used with a Pro64 digital I/O device, the system

can lock to any sample rate within one of the three ranges shown in the table

below.

Pro64 Series Supported Sample Rates

Sample Rate

Minimum

Maximum

44.1/48kHz

39.7kHz

52kHz

88.2/96kHz

79.4kHz

104kHz

176.4/192kHz

158.8kHz

208kHz

Pro16 Outputs

The current Pro64 sample rate has a direct effect on the number of Pro16

channels that can be output from the A‑Net Systems Interface. The Pro16

outputs are in banks of sixteen channels.

Pro64 Sample Rate

Pro16 Outputs Available

44.1kHz

1‑16, 17‑32, 33‑48, 49‑64

48kHz

1‑16, 17‑32, 33‑48, 49‑64

88.2kHz

1‑16, 17‑32

96kHz

1‑16, 17‑32

176.4kHz

1‑16

192kHz

1‑16

The Pro16 Output LEDs on the front panel of the ASI will display the available

Pro16 outputs, based on the current Pro64 network sample rate.

Pro64/Pro16 Channel Mapping

At 44.1/48kHz, all four Pro16 outputs on the ASI can be used. Each is mapped

in a one‑to‑one relationship to its Pro64 channel counterpart (Pro64 channel

1 is output as Pro16 channel 1; Pro64 channel 23 is output as Pro16 channel

23, etc.). No channel remapping is possible between the two data formats.