ADVANCED DISPLAY WEB PAGE










Days since last full charge or equalize. Equalize
day counter resets upon starting equalize.

Day counter accuracy is +1 / -0 days. Day counter
transitions occur following each 24 hour period from
charge controller boot. Consider rebooting charge
controller very late at night to improve perceived
accuracy. Maximum range is 255 days which is
also shown if days are unknown.

Captures minimum and maximum battery voltage
since last cleared.

Captures total output amp-hours of all charge
controllers on the IPN network since last cleared.

Serves as battery “odometer” capturing total
discharge amp-hours since last cleared. Value
computed by IPN-ProRemote and saved to IPN-
ProRemote non-volatile memory once per day.

Present status of all charge controllers on the IPN
network. If charge controllers are present in the
system and communicating data for that charge
controller will be shown. If data is unavailable
because a particular charge controller is not
installed or not operating dashes (

– –

) are

displayed. (Charge controllers without digital temp
sensor always read -55

°C.)

Datalog control panel. Shows number of records
available, sets time period between datalog records
& downloads/clears datalog file. Default time period
of 24.2 hours should be used for a desired datalog
period of one day. Entering a setting of 0.0 hours
disables record collection and return the word
DISABLED in the setting box.

Do not press SET with the word DISABLED in the
setting box or an unusual numeric value will be
entered.