A7-Core Input Terminal B10-Core Input Terminal

8.1 Description of 7-Core Terminal

1.DC12V: red 2.GND: black

5.R+ (communication+): orange 3.R- (communication-): yellow 4.Null

6.V+: (VF+) 7.V-: (VF-)

8.2 Description of 10-Core Terminal

1.Alarm-1 in: red 2.Alarm-2 in: orange

3.Alarm-3 In: yellow 4.Alarm-4 In: green 5.NC

6.Alarm In COM: black 7.Alarm Out COM: black 8.NC

9.Alarm NO out: blue 10.Alarm NC COM: pink

8.3 Description of 10-Core Socke

a. When 7-core input takes DC voltage, 10-core socket is free and there is no alarm system;

b. When 7-core system takes AC 24V voltage, 10-core socket is used for the alarm system.

V. Installation of the Product

5.1 Drawing of the Sizes of the Product

Outline Sizes of the Pan/Tilt

5.2 Installation Style of the Product