VIII. Normal Troubles and Remedies

Troubles

Possible Causes

Remedies

Power supply
damaged of
insufficient electric
power

Replace

Wrong connection of
power supply wires

Make correction

No action and images after
switching on

Engineering circuits
failed

Remove

Mechanic trouble

Repair

Pan/tilt may be
inclining

Re-fix

Abnormal self-inspection,
images with humming of
motor

Insufficient electric
power

Replace with qualified power supply

Wrong connection of

VF circuit

Make correction

Bad contact of VF
circuit

Remove

Normal self-inspection, no
images

Camera damaged

Replace

Wrong connection of
control signal wires

Make correction

Mismatched address

Re-select

Successful self-inspection
without control

Mismatched

protocol Make mismatch of protocol and

controller and restart

Bad contact of VF
circuit

Remove

Unstable images

Insufficient electric
power

Replace

Abnormal
self-inspection

Restart

Bad contact of control
circuit

Remove

Operation of main
machine has problem

Restart the main machine

Dome pan/tilt out of
control

Much load or
communication
distance too far

1. Connect 120Ω resistor of the

farthest dome pan/tilt from the
controller and disconnect all
other resistors;

2. Add coding divider

Auto/Manual of infrared
lamp ineffective

Infrared lamp may be
damaged

Rework

Some common troubles and their causes and remedies are listed above for your reference. Should you meet

other special problem, you can contact with the dealer directly for technical support.