6 | maintenance – GEA Bock F18 User Manual

Page 20

Advertising
background image

20

D
GB
F
E

96246-07.2014-DGbRu

6.1 Preparation

6.2 Work to be carried out

6| Maintenance

Accessories available can be found on the Internet at www.bock.de.

6.4 Accessories

WARNING

Before starting any work on the compressor:

Switch off the compressor and secure it to prevent a restart.
Relieve compressor of system pressure.
Prevent air from infiltrating the system!

After maintenance has been performed:

Connect safety switch.
Evacuate compressor.
Release switch lock.

To guarantee optimum operating safety and service life of the compressor,

we recommend perfor-

ming service and checking work at regular intervals of time:

Oil change:

-

In series plants produced in the factory not mandatory.

-

In field installations or operating in the application limit range, first oil change after approx.
100 - 200 operating hours, then approx. every 3 years or 10,000 - 12,000 operating hours.
Dispose of old oil according to the regulations, observe national regulations.

Annual checks: Oil level, tightness, running noise, pressures, temperatures, function of auxiliary
devices such as a oil sump heater, pressure switch. Comply with the national regulations!

F18 / ...

2735

3235

Designation

Ref. No.

Ref. No.

Set gaskets

80904

80905

Valve plate kit

80894

80895

Kit piston / connecting rod

80890

80891

Kit capacity regulator LR12

80889

80879

Oil pump kit

80116

Kit shaft seal

80897

Oil SP 46, 1 liter

02279

Oil SE 55, 1 liter

02282

6.3 Spare parts recommendation

Only use genuine Bock spare parts!

Advertising