A

max. 30°,
max. 2 minutes

a

max. 15°,
continuous
operation

Fig. 14

A

a

A

a

a

A

a

A

4.3 Maximum permissible inclination

ATTENTION! Poor lubrication can damage the compressor.

Respect the stated values.

4 | Compressor assembly

The

discharge and suction line valves have stepped internal

diameters so that pipes with standard millimetre and inch
dimensions can be used. The depth of pipe insertion will
depend on the dimension.

The connection diameters of the shut-off valves are rated for

maximum compressor output.

The required pipe cross-section must be

matched to the output. The same applies for non-return valves.

Fig. 15: Stepped
internal diameters

4.4 Pipe connections

ATTENTION! Overheating can damage the valve.

Remove the pipe supports from the valve for soldering. Solder

them with protective gas to prevent oxidation products (scale).