4 | compressor assembly – GEA Bock HG22e A User Manual

Page 13

Advertising
background image

D
GB
F
E

13

96192-11.2014-DGbFE

Fig. 17

Fig. 18

Valve spindle seal

Release

Tighten

Pipe connection

Pipe connection

4.8 Operating mode of the lockable service connections

Fig. 19

Opening the shut-off valve:
Spindle: turn to the left (counter-clockwise) as far as it will go.
—> Shut-off valve completely opened / service connection closed.

Fig. 20

Opening the service connection
Spindle: Turn ½ - 1 turn to the right clockwise.
—> Service connection opened / shut-off valve opened.

Service connec-
tion closed

Connection
blocked

Spindle

Service connec-
tion opened

Spindle

Connection
open

Compressor

Compressor

4 | Compressor assembly

4.7 Operating the shut-off valves

Before opening or closing the shut-off valve, release the adjustable valve spindle seal by approx.

¼ of a turn counter-clockwise.

After activating the shut-off valve, re-tighten the adjustable valve spindle seal clockwise.

Advertising