Chateau, Mantels, Clearance to combustibles – CFM Corporation DVT38IN User Manual

Page 5: Locating your fireplace

Advertising
background image

5

Chateau™

20011956

A) Flat on wall

B) Cross corner

C) **Island

D) *Room divider E) *Flat on wall corner

F) Chase installation

Y) 6” minimum
NOTE (Fig. 3):
** Island (C) and Room Divider (D) installation is possible as long as
the horizontal portion of the vent system (X) does not exceed 20’ (6
m). See details in Venting Section.
* When you install your gas fireplace in (D) Room divider or (E) Flat
on wall corner positions (Y), a minimum of 6” (152 mm) clearance
must be maintained from the perpendicular wall and the front side
edge of the fireplace.

Appliance
Top Standoffs ..................................................... 0” (0 mm)
Bottom* .............................................................. 0” (0 mm)
Side Standoffs .................................................... 0” (0 mm)
Back Standoffs ................................................... 0” (0 mm)
Front............................................................. 36” (914 mm)
Top of Unit to Ceiling .................................... 36” (914 mm)
Venting
Horizontal Termination through-a-side wall:
Vertical Sections:
Sides ...................................................... 2¹⁄₂” (64 mm)
Horizontal Sections:
Top ......................................................... 3¹⁄₂” (89 mm)
Bottom ................................................... 1¹⁄₂” (38 mm)
Sides ...................................................... 2¹⁄₂” (64 mm)
Vertical Vent Application:
Sides ..................................................... 1¹⁄₂” (38 mm)
* To prevent the potential for odors, do not use epoxy-filled
particle board directly under this fireplace.

Mantels

The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This
also applies to the distance between the mantel leg (if
fitted) and the fireplace.
For the correct mounting height and widths refer to
Figs. 4a and 4b, the following Mantel Charts.
Noncombustible mantels and legs may be installed at
any height and width around the appliance.
When using paint or lacquer to finish the mantel, such
paint or lacquer must be heat resistant to prevent
discoloration.

Clearance to Combustibles

Y

E

A

B

C

D

F

Y

B

X

LU584-1

Locating unit

2/4/99 djt

Locating Your Fireplace

Fig. 3 Locate gas fireplace.

LU584-1

Fig. 4a Combustible mantel minimum installation.

A

B C D E

V

W

X

Y

Z

CFM146c

DVT44

mantal chart

Mantel Chart

Mantel Shelf

Mantel from Top

Ref. or Breast Plate Ref. of Comb. Chamber

Depth

V

10” (254 mm)

A

10” (254 mm)

W

9” (229 mm)

B

9” (229 mm)

X

8” (203 mm)

C

8” (203 mm)

Y

7” (178 mm)

D

7” (178 mm)

Z

6” (152 mm)

E

6” (152 mm)

CFM146c

Combustible

Framing and Fin-

ish Wall Above

Standoffs

Standoff

Top of Sheet

Metal

Noncombustible Fin-

ish Material

(Such as Dura Rock)

Fireplace Front

May use combus-

tible facing mate-

rial in this area

J

F

G

H

I

CFM164b

Mantel Leg Char

DVT44

4/9/03 djt

Mantel
Leg

CFM164b

CFM170

DV Builder Front

View

O

N

M

L

K

CFM170a

Fig. 4b Combustible mantel leg minimum installation.

Mantel

Mantel Leg from Side

Ref.

Leg Depth

Ref.

of Comb. Opening

F

12” (305 mm)

K

12” (305 mm)

G

9” (229 mm)

L

9” (229 mm)

H

6” (152 mm)

M

6” (152 mm)

I

4” (102 mm)

N

4” (102 mm)

J

3” (76 mm)

O

3” (76 mm)

Side of Fireplace

Noncombustible

Finish Material

Advertising