The TWA 1000-M Water Activated Table Top Dispensers are fabricated with high quality components
that provide trouble-free operation for a long period of time. However, should a problem occur, we
recommend that you consult the following table. If the problem you encounter is not discussed in this
table, call Interpack Technical Support. (see page 2 of this document).

Trouble

Possible Causes

Solutions

Tape is jamming

Debris in the tape path

Adhesive build up

Pressure plate missing or installed
incorrectly

Too much weight on the moistening
brush

Cutter blade not adjusted properly

Side guides set incorrectly

Clean Tape Path (see preventive
maintenance)

Clean tape path, moistening
brush and brush pot

Install pressure plate (see tape
threading)

Reduce brush weight setting (see
set up)

Re-adjust cutter blade (see
preventive maintenance)

Loosen or tighten as necessary
(see set up)

Tape does not cut
cleanly.

Debris in the cutter blade

Cutter blade not adjusted properly

Blade dull

Weak Return Spring

Clean cutter blade (see
preventive maintenance)

Re-adjust cutter blade (see
preventive maintenance)

Replace cutter blade (see
preventive maintenance)

Replace Return Spring

Tape is too dry

Dirty brush

Water level in brush pot too low

Clean moistening brush (see
preventive maintenance)

Adjust water level in brush pot
(see set up)

Tape is too wet

Water level in brush pot too high

Adjust water level in brush pot
(see set up)