Simulation Mode

You can use this function to check that the I/O control cable has been wired
correctly.
Main screen

1

On the main screen, while pressing the
[MODE] button, press the
W button five times.

[51.out] is displayed on the main display (upper

level).

While pressing

the [MODE]

button, press the
W

button five

times.

2

Use the S/T buttons to display the signal that
you want to output in the sub display (lower
level). The signal will be output when it is
displayed. Press the [MODE] button to
proceed to the next step.

[MODE] button

3

When you turn ON external input 1 to external
input 4, the corresponding part of the display
will change from [_] to [o].

From the right, the parts correspond to external

inputs 1, 2, 3, and 4.

Press the [MODE] button to proceed to the next step.

(Example) [___o] indicates that external input 1 is

on.

[o_o_] indicates that external inputs 2

and 4 are on.

[MODE] button

4

The upper limit, middle value, and lower limit
of the analog output are generated. This is not
displayed when the analog output is turned
OFF. Press the [MODE] button to proceed to
the next step.

(Example) When the analog output setting is 0 to 5 V

5 V is output for Hi, 2.5 V is output for Mid,

0 V is output for Lo, and 5.5 V is output for

Err.

[MODE] button

5

[END] is displayed on the sub display (lower
level). Press the [MODE] button to complete
the procedure and return to the main screen.

HOLD

HI

V

kV

ALARM

BANK

ZERO SHIFT

TIMING

TEMP

%RH

HI

LO

R.V.

0

1

2

3

LO

GO

off

51.out

Setting value

Description

OFF

No signal is output.

HI

The HI signal is output.

GO

The GO signal is output.

LO

The LO signal is output.

ALM

The alarm signal is output.

----

52.in

Hi

53.AnG

Setting

value

Description

Hi

The upper limit of the analog output is

generated.

Mid

The middle value of the analog output is

generated.

Lo

The lower limit of the analog output is

generated.

Err

The output value when an error occurs is

output.

HOLD

HI

V

kV

ALARM

BANK

ZERO SHIFT

TIMING

TEMP

%RH

HI

LO

R.V.

0

1

2

3

LO

GO

Return to the

main screen.

5.

Specifications

This chapter describes the specifications, circuit diagrams, and dimensions of the
SK Series.

Specifications

„

Sensor head

*1 Even in the measurement area, if the distance to the detection target is smaller than the

reference distance, measurement cannot be performed up to the upper limit of the

measurement range.

*2 When measured an average of 256 times, this value is ±100 V or less in high-precision

mode and ±1 kV or less in wide-range mode, and ±10% (indicated value) in other ranges.

*3 The measurement accuracy range is ± 30 kV.

*4 At 25°C and with a humidity of 50%RH

*5 OP-87934 is necessary.

*6 This is when ±100 V or less, and ±10% (indicated value) in other ranges.

„

Sensor amplifier

*1 Select one from ±5 V, 1-5 V, 0-5 V, 4-20 mA.

*2 The four external input wires are assigned to arbitrary inputs.

Rated novoltage input: ON voltage of 2 V or less, OFF current of 0.02 mA or less.

Rated voltage input: max. input rating of 30 V or less, ON voltage of 7.5 V or more, OFF

current of 0.05 mA or less.

*3 Rated NPN open-collector output: max. 50 mA/ch (20 mA/ch when expansion units are

connected), 30 V or less, residual voltage of 1 V or less (1.5 V or less when five or more

expansion units are connected).

Rated PNP open-collector output: max. 50 mA/ch (20 mA/ch when expansion units are

connected), supply voltage or less, residual voltage of 2 V or less (2.5 V or less when five or

more expansion units are connected).

*4 Power supply voltage of 20-30 V when five or more expansion units are connected.

*5 Max. 11.3 W when eight units and the DL Series are connected.

Model

SK-050

Electrification
potential
measurement

Measurement mode

High precision

Wide range

Reference distance for
measurement

25 mm

100 mm

Measurement distance

5 to 50 mm

60 to 120 mm

Measurement range

*1

±2 kV

±50 kV

Measurement accuracy

*2

±10 V

±100 V

*3

Sampling time

Approx. 1.4 ms

Temperature
measurement

Measurement range

0 to 50°C

Measurement accuracy

*4

±1°C

Minimum display unit

0.1°C

Sampling time

1 s

Humidity
measurement

Measurement range

10 to 85% RH

Measurement accuracy

*4

±5% RH

Minimum display unit

0.1% RH

Sampling time

1 s

Ion balance
measurement
mode

*5

Ion balance measurement
range

±1 kV

Measurement accuracy

*6

±10 V

Minimum display unit

1 V

Environmental
resistance

Ambient temperature

0 to 50°C (no freezing and no condensation)

Ambient humidity

10 to 85%RH (no condensation)

Materials

Main body case: PC, metal part: SUS, cable: PVC

Weight

Approx. 35 g

Model

SK-1000

SK-1050

Type

Mounting DIN rail.

Main unit/expansion unit

Main unit

Expansion unit

Display

Minimum display unit

0.001 kV

Display range

±99.999 kV to 99 kV (Four-stage selection possible)

Analog voltage output

*1

±5 V, 1-5 V, 0-5 V,

Load resistance: 100Ω

Analog current output

*1

4 to 20 mA

max. load resistance 350Ω

Control
input

*2

Zero shift input

No-voltage input

Timing input
Reset input
Bank input

Control
output

*3

Judgment output

Open-collector output

(NPN/PNP switchable; NO/NC switchable)

Alarm output

Open-collector output (NPN/PNP switchable, N.C.)

Power
supply

Supply voltage

*4

10 to 30 VDC including

10% ripple (P-P)

Supplied from the main

unit.

Current consumption
(Excluding the load
current of each output.)

*5

1650 mW or less

(at 30 V, 55 mA max)

1170 mW or less

(at 30 V, 39 mA max)

Environmental
resistance

Ambient temperature

0 to 50°C (no freezing and no condensation)

Ambient humidity

10 to 85%RH (no condensation)

Materials

Main body case / front cover: PC, key top: POM,

cable: PVC

Weight (Including accessories)

Approx. 150g

Approx. 140g