Erase All Codes -- Sub-Mode 0

Caution: This is a destructive Programming Mode. Completing the following steps will erase all

Access Codes except for the factory default Master Code (1 2 5 1). Use with Caution.

DETAILS: This Sub-Mode should rarely be used unless you want to completely erase all Access Codes entered. This

action will not change the Master Code.

To erase all Access Codes and Function Codes

• Enter the Master Code (The 1 2 5 1 cannot be deleted)

• Enter the numeral 0

• Both the Red and Yellow LEDs will fl ash several times and the unit will sound a GOODTONE once all of the

memory is cleared.

• Enter the Master Code to complete the process

• If the sequence is not validated by the unit, you will receive an ERROR TONE and be exited from this program

mode

• A GOOD TONE will sound to indicate all memory is cleared.

RESETTING THE DK UNIT

The Advantage DK has two special reset types: Master Reset and Unit Reset. Choose the procedure that you want

to use carefully.

Master Reset

• Should be used if the Master Code is lost or forgotten. The procedure will reset the Master Code to the 1 2 5 1.

• Should be used if the unit is in the Latch or Sleep Mode and the Latch or Sleep code is lost or forgotten.

• When a Master Reset is performed, Access Codes and Functions Codes are retained in memory and the unit

does not require complete reprogramming.

Unit Reset

• Should only be used if the Advantage DK is to be completely reset back to factory default settings.

• ALL ACCESS and FUNCTION CODES ARE LOST during a Unit Reset.

• The Master code is reset to 1 2 5 1 following a Unit Reset.

MASTER RESET

Follow these steps exactly. If you make an error, an ERROR will occur (you will hear a low ERROR tone) and you will

need to start over from Step 1.

1. Open the unit face plate using the key provided.

2. Disconnect power from the unit by gently pulling the wire harness connector away from the board. Make sure

to note the orientation of the connector.

3. Press and hold down the RESET button and reconnect power to the board by gently sliding the harness

connector back into place on the circuit board(you will hear 1 tone), then release the RESET button. (See

location Board Layout diagram, page 22 )

4. Press the star (*)(*)(*) key three times.

5. The Master Code is now reset to the factory default (1 2 5 1)

6. Close the face plate.

7. Program a new Master Code if you choose to do so. Be sure to make a note of the new Master Code.

UNIT RESET

NOTE: ALL ACCESS CODES and FUNCTION CODES are lost when performing a Unit Reset.

Follow these steps exactly. If you make an error, an ERROR will occur (a low-pitch ERROR tone will sound) and you will

need to start over from Step 1.

1. Open the faceplate.

2. Disconnect the power from the unit by gently pulling the wire harness away from the board. Make sure to

note the orientation of the connector.

3. Press and hold down the RESET button and reconnect power to the board by gently sliding the harness

connector back into place on the circuit board, then release the RESET button. (See location Board Layout

diagram, page 22)

4. Enter (#) (ã) (#) (Pound, Star, Pound)

5. The unit will respond with a GOOD TONE

6. Enter the MASTER CODE (1 2 5 1) from the keypad. The unit will fl ash the LED’sseveral times and then go into

an endless cycle of tones.

7. While the cycle of tones continues, disconnect and then immediately reconnect power to the unit using the

circuit board harness connector. The unit will then go through the “First Time Power Up” sequence. (See

page

5).

8. The DK is now completely reset. All programming is erased.

Advertising