SubMode 306 (TOGGLE 3 STRIKES ON/OFF)

NOTE: From the factory, 3 strikes is disabled.
DESCRIPTION: This feature is desirable to keep unwanted persons from successively entering codes until they “hit” a
programmed access code. By selecting this function you enable a 1 1/2 minute lock out time if 3 incorrect codes are
entered successively within a 3 minute period. When this occurs, the LED’s will flash and a high pitched alarm will be
generated from the unit for 30 seconds. The unit will then shut down for 1 minute.
To toggle the 3 STRIKES feature on and off enter the 5 digit “MASTER CODE” followed by submode “306”. At this time
the unit will respond with a QUICK BEEP if the 3 strikes is currently enabled. If you wish to toggle the state, reenter the 5
digit “MASTER CODE” other wise press # to exit.

(MASTER CODE) + 306(*) + (MASTER CODE)

(*) 1 BEEP AND RED LED ON = FEATURE ENABLED

(*) 2 BEEPS AND RED LED OFF = FEATURE DISABLED
Should you make an entry error, simply press the * key and reenter the correct data. An ERROR will occur and the unit
will exit the program mode if the second master code is incorrect.

“307”

SubMode 307 (TOGGLE SPLIT RELAY ON/OFF)

NOTE: From the factory, SPLIT RELAY is disabled. Also if using only one slave connect it to the SLAVE 2 terminals.
DESCRIPTION: The split relay feature is desirable when an entry and exit gate exist with a master/slave operating on
two different outputs. When this feature is enabled all access codes entered from the master unit and slave 1 will
activate relay A and all access codes entered from slave 2 will activate relay B.

To toggle the SPLIT RELAY feature on and off enter the 5 digit “MASTER CODE” followed by submode “307”. At this time

the unit will respond with a QUICK BEEP if the split relay feature is enabled. If you wish to toggle the state, reenter the 5
digit “MASTER CODE” other wise press # to exit.

(MASTER CODE) + 307(*) + (MASTER CODE)

(*) 1 BEEP AND RED LED ON = FEATURE ENABLED

(*) 2 BEEPS AND RED LED OFF = FEATURE DISABLED
Should you make an entry error, simply press the * key and reenter the correct data. An ERROR will occur and the unit

will exit the program mode if the second master code is incorrect.

“308”

SubMode 308 (TOGGLE ANTI-PASSBACK ON/OFF)

NOTE: From the factory, APB is disabled.
ABOUT APB: Antipassback is used to keep end users from passing their codes back allowing other users to gain
access onto the property. The ADVANTAGE DKS II unit incorporates a true Antipassback feature in which an end
user enters his entry code from the master unit or slave 1 and then MUST enter it from slave 2 to exit. If the code is
reentered again from the master unit or slave 1, it will be logged as an error and access will be denied. The same
applies to the slave unit. From the initial entry of the code, the APB status of that code is logged into the system and
each time the code must be entered from the opposite keypad.

To toggle the ANTIPASSBACK feature on, enter the 5 digit “MASTER CODE” followed by submode “308”. At this time the

unit will respond with 2 BEEPS and the red LED will be off if the antipassback feature is disabled. If you wish to toggle

the state, enter a 5 digit “APB MASTER CODE” between 0 and 65535 followed by the “NUMBER OF SLAVES” connected

to the system.

(MASTER CODE) + 308(*) + (APB MASTER CODE) + (NUMBER OF SLAVES)

(*) 1 BEEP AND RED LED ON = FEATURE ENABLED

(*) 2 BEEPS AND RED LED OFF = FEATURE DISABLED

Example: 01251 + 308 + ????? + 2