Group 400 (special function) – American Access Systems Advantage DKSII - Regular - 24-1000i User Manual

Page 15

Advertising
background image

Page 15 American Access Systems / Security Brands, Inc.

“309”

SubMode 309 (QUIET MODE)

NOTE: From the factory, QUIET MODE is enabled.
DESCRIPTION: If you want to hear the good or bad beeps at your desk when an access code is entered at the slave
keypad you can disable the quiet mode. This sub-mode can be toggled on or off by pressing:

(MASTER CODE) + 309(*) + (MASTER CODE)

(*) 1 BEEP AND RED LED ON = FEATURE ENABLED

(*) 2 BEEP AND RED LED OFF = FEATURE DISABLED

GROUP 400 (SPECIAL FUNCTION)

“401”

SubMode 401 (PRINT OUT ALL CURRENT ACCESS CODES)

NOTE: THE UNIT MUST BE INTERFACED TO A PRINTER TO USE THIS SUBMODE.
DESCRIPTION: This sub-mode is used to print out all access codes in the system either entered by hand or randomly
generated.

NOTE: To print out manager and relay B codes see sub-mode “405”.

To print out all access codes enter the 5 digit “MASTER CODE” followed by submode “401”.

(MASTER CODE) + 401

“402”

SubMode 402 (PRINT AUDIT TRAIL ON SPECIFIC CODE)

NOTE: THE UNIT MUST BE INTERFACED TO A PRINTER TO INVOKE THIS SUBMODE.
DESCRIPTION: This sub-mode is used to print out the audit trail history) of a specific code. The unit goes through the
1000 code history buffer and finds when the specific code has been used and prints the times and dates.

To print out the history of a specific code enter the 5 digit “MASTER CODE” followed by submode “402” followed by the

“SPECIFIC CODE”.

(MASTER CODE) + 402 + (SPECIFIC CODE)

Example: To print out the history of code 13156 enter:

“MASTER CODE” + 402 + 13156

1 - 9600 baud

2 - 4800 baud

3 - 2400 baud

4 - 1200 baud

“403”

SubMode 403 (SET PRINTER BAUD RATE)

The default baud rate is 9600. To program in a different baud rate choose from these 4 choices and put in the number

1 thru 4.

(MASTER CODE) + 403 + (1,2,3 OR 4)

Example:

To change to 2400 baud:

MASTER CODE” + 403 +