Master reset, Unit reset, The idle mode – American Access Systems Prox Card Reader - 23-206 User Manual

Page 8: The program mode, The * and # keys

Advertising
background image

Page 8 American Access Systems / Security Brands, Inc.

MASTER RESET

Follow these steps precisely. If you make an entry error, the unit will ERROR and you will have to start over.

(1).

Disconnect power from the master board

(2).

Reconnect power to the board while holding down the

RESET BUTTON

(3).

Release the reset button and enter * * * from the keypad.

The unit will issue a GOODBEEP and the master code will be set back to 1 2 5 1. If the unit was locked in the sleep,

lockA, or lockB mode, the unit will be released and returned to the idle state.

UNIT RESET

(!!! WARNING: ALL ACCESS & FUNCTION CODES WILL BE DELETED FROM MEMORY !!!)
Follow these steps precisely. If you make an entry error, the unit will ERROR and you will have to start over.

(1).

Disconnect power from the master board

(2).

Reconnect power to the board while holding down the RESET BUTTON.

(3).

Release the reset button and enter # * # from the keypad.

(4).

Enter the MASTER CODE from the keypad. (The unit will go into an endless cycle of

beeps).

(5).

Disconnect & Reconnect power to the unit. (The unit will go through the “FIRST TIME

POWER UP” sequence (See “HOOKUP STEPS”, page 5, step C).

THE IDLE MODE

The idle mode is the normal mode of operation. When in this mode the unit sits and waits for data from the keypad.

In this mode you will have approximately 3 seconds between key presses. If this time is exceeded you will receive an

ERROR.

THE PROGRAM MODE

The program mode is the mode of operation in which you will enter, delete, or change your codes or set specific

features of the unit. The program mode is accessed by entering the “MASTER CODE” from the MASTER unit. You will

receive a QUICKBEEP and the yellow LED will come on indicating that you are in the program mode. In this mode you

will have approximately 30 seconds between key presses. If this time is exceeded, you will receive and ERROR and be

exited from the program mode.

THE * AND # KEYS

The * and # keys serve specific functions while in the idle or program mode. The * key is always the clear key and a

double beep will be heard when depressed. You should use this key if you make an entry error. The # key also serves

as a clear key in the idle mode. In the program mode however, it serves as the exit key and will at any time, when

depressed, exit you from the program mode.

Advertising