PROGRAMMING

A person desiring access to the program mode will enter the present MASTER CODE. If the master code is valid

the yellow LED will come on and the individual will be prompted with a QUICKBEEP to enter a 3 digit number

corresponding to a SUBMODE. There are 4 groups of SUBMODES. Group 100 is for PROGRAMMING CODES, group 200

is for DELETING CODES, group 300 is MISCELLANEOUS SETTINGS and GROUP 400 is PRINT FUNCTIONS. There are a total

of 26 different submodes to choose from. They are as follows:

GROUP 100 SUBMODES (PROGRAMMING CODES)

SUBMODE

DESCRIPTION

100

Program Access Cards (Block Format)

101

Program Managers Card(s) (Block Format)

102

Program Sleep Card(s) (Block Format)

103

Program Relay A Latch Card(s) (Block Format)

104

Program Relay B Latch Card(s) (Block Format)

105

Program Relay B Card(s) (Block Format)

106

Set System Facility Code (3 max.)

108

Change System Master Code

109

Change Quick Entry Master Code

110

Change Quick Delete Master Code

GROUP 200 SUBMODES (DELETING CODES)

SUBMODE

DESCRIPTION

200

Delete Cod Delete Card(s) (Block Format)

299

Clear APB status

GROUP 300 SUBMODES (MISCELLANEOUS)

SUBMODE

DESCRIPTION

300

Set Relay A Output Time (1/2 to 99 seconds)

301

Set Relay B Output Time (1/2 to 99 seconds)

302

Set Clock Time (Military Format)

GROUP 400 SUBMODES (PRINT FUNCTIONS)

SUBMODE

DESCRIPTION

400

Print Audit Trail (Entire Contents of History Buffer)

401

Print Out All Current Access Cards

402

Print Audit Trail on Specific Card

403

Set Printer Baud Rate

404

Red Printing on Invalid Cards (For AAS idp562 Citizen Printer Only)

405

Print Out Current Unit Configuration (Prints out Status of Split Relay,

APB, Current Baud Rate, All Manager’s and Second Relay Cards)

499

Clear Entire History Buffer