Figure 13: verify parameter setting – Ameri-King AK-451-ELT User Manual

Page 61

Advertising
background image

61

2.4.6

GPS Position Test (If GPS is connected) (for using TS-451 Computer

Test Set or equivalent):

Note: Per FCC Regulation, this test should be conducted inside a RF shielded
room or an ELT RF shielded box. Dummy 50 ohm Load should be used.

Connect the AK-451 with ELT Computer Test Set TS-451.

Turn the switch of the ELT to “ON” position.

Verify the following setting (See Figure 13.) From the Hyper Terminal
window (or equivalent RS-232 window), Click File -> Properties -> Settings
tab. Click OK to go back to Hyper Terminal window.

Figure 13: Verify parameter setting


Waiting for 50s, verify the 36 Hex digits (ignore first 6 digits). The last 30 Hex digits
will be used for Cospas-Sarsat Decode program, in order to see the Latitude,
Longitude Position.

IMPORTANT NOTE: IN NORMAL OPERATION, THE MAIN SWITCH
LOCATED ON THE ELT MAIN UNIT MUST BE SELECTED AT “ARM”
POSITION AT ALL TIMES.