3.3.5

TRANSMITTER FUNTIONAL TEST FOR ELT-(S) ONLY


The ELT-(S) should be tested every month.

3.3.5.1 Main Switch ON / OFF / SELF TEST Operation:

The ELT-(S) has an "OFF" position. This allows the beacon to be handled or shipped
without 'nuisance' activation. Care should be taken when transporting or shipping the
ELT-(S) not to move the switch or to allow packing material to become lodged such
as to toggle the switch.
Main Switch, alternate / alternate / momentary positions:

"ON:" Alternate position. ELT-(S) transmits immediately. Green ON light on the
main unit flashes, 1 second ON, 4 seconds OFF. The ELT swept Tone must be
heard on the 121.5 MHz VHF Radio.

"OFF:" Alternate position. The ELT-(S) is turned off.

"SELF TEST:" Momentary position. ELT-(S) self-test is confirmed after the
switch is held for 25 seconds. If the self-test is passed, the Green ON light must
be extinguished. ELT swept Tone must be silent on the 121.5 MHz VHF Radio.


The ELT-(S) system is fully self-tested.