Ameri-King TS-451 User Manual

Page 8

Advertising
background image

AMERI-KING CORPORATION

17881 Sampson Lane, Huntington Beach, CA 92648 - Tel (714) 842-8555 - Fax (714) 842-4235 - Email:

[email protected]

8

ELT CODING PROGRAMMING, ID READER AND MAINTENANCE TEST


Important Note: These tests should be performed only within an RF Screen Room or
Facility providing shielding of RF Emissions.

1.

Setup
Use provided cable to connect the ELT (RJ-12 port) to the mini PC (USB port)


2.

ELT Coding Programming

2.1

Double-Click “AK451” Icon to run the program. The programming window
appears as below:

Figure 1


Note:
If you don’t see the window above, you may try the other USB port.

2.2

Set the ELT main switch to “ARM” position.

2.3

Verify the LED ‘ON’ light illuminates for 4 seconds.

2.4

At the “:>_” prompt, type: cn Password command then press “Enter” to go to
main menu. Must type this command within next 20 seconds after the command
prompt appears.

Note 1: Please contact Ameri-King for Password, via Email or fax or call.
Note 2: If there is no programming command input in this time window, the ELT will enter the
Self-Test mode, and you cannot program the ELT. In this case, set the ELT switch to “OFF
position and start again from step 2.2.