background image

Ice in Trough

• Check fuses or circuit breakers.

• Check to see if there are any gaps that allow cold air to enter the base of the

drinker.

- Make sure the fountain is sealed from wind between the concrete platform and

bottom of the drinker.

- Make sure there are no air leaks around the access door.

• Check to make sure that you have a full 120 volts at the drinker and that the 120

volts are maintained when the submersible heater is on.

Water Freezing

in the Valve or

Supply Line

• Make sure the supply line is properly installed.

- Riser tube with supply line centered, and there is an air space between riser tube

and supply line.

- Horizontal supply line is at least 1' below frost line.

• Check for missing or damaged insulation.

• Check for air gaps against wind penetrations.

- Make sure the fountain is sealed from wind between the concrete platform and

bottom of the drinker.

- Make sure there are no leaks around the access door.

- Make sure that the latches are holding the float cover securely to drinker. If the

latches are loose, adjust spring tension on the latch and, if necessary, bend the
latch ends in vise thus enabling the latches to hold the cover tighter.

Valve Won’t

Stop Dripping

or Shut Off

• Check the float adjustment. Check for waterlogged float, or float rubbing on side of

the valve compartment. Ensure that the float moves freely.

• Disassemble valve and check for sand or scale in valve rubber. Also check valve

orifice outlet for wear and damage. A screen or filter may be required with sandy or
scaly water. Please refer to the valve cleaning instructions supplied with your
drinker.

• Turn valve rubber over and re-assemble.

• Check for excessive water system pressure (greater than 55 psi). If needed, install

a pressure regulator, available at most plumbing shops.

Low Water Flow

• Check that the valve inlet is not plugged or supply hose is not kinked.

• Check system pressure from supply hose by installing a tee and a pressure gauge

directly in front of the valve and then check pressure drop when valve is open. A
severe pressure drop indicates a restriction or undersized supply system.

• Check that shut off valves are fully open.