12 Installer Guide

20 Heat Set Point Upper Limit – Selects the heating set point upper adjustment limit.

21 Cool Set Point Lower Limit

[note 6]

– Selects the cooling set point lower adjustment limit.

Warning

Read Before Testing

• Do not short (or jumper) across terminals on the gas valve or at the heating or cooling system control board

to test the thermostat installation. This could damage the thermostat and void the warranty.

• Do not select the COOL mode of operation if the outside temperature is below 50º F (10º C). This could

possibly damage the controlled cooling system and may cause personal injury.

• This thermostat includes an automatic compressor protection feature to avoid potential damage to the

compressor from short cycling. When testing the system, make sure to take this delay into account.

NOTE: The compressor delay can be bypassed by pressing the reset button on the front of the thermostat.
All user settings will be returned to factory default, however all Installer settings will remain as originally
programmed in section 4.

1 Press the

SYSTEM

button until the thermostat is in HEAT mode.

2 Using the SpeedBar

®

raise the set temperature a minimum of 3 degrees above the current room

temperature. The system should start within a few seconds. With a gas heating system, the fan may

not start right away.

3 Press

SYSTEM

until the thermostat is in the OFF mode. Allow the heating system to fully shut down.

4 Press

SYSTEM

until the thermostat is in the COOL mode.

5 Using the SpeedBar lower the set temperature a minimum of 3 degrees below the current room

temperature. The system should start within a few seconds (unless compressor short cycle protection

is active – See note above).

6 Press

SYSTEM

until the thermostat is in the OFF mode. Allow the cooling system to fully shut down.

7 Press

FAN

until the thermostat is in FAN ON mode. The system fan should start within a few seconds.

8 Press

FAN

until the thermostat is in FAN AUTO mode. Allow the system fan to turn off.

5 System Testing

Advertising