Read & understand sefety decals, Symptom, Possible causes – CAMCORP Blower Package with Sutorbilt Blower User Manual

Page 11: Possible sources

Advertising
background image

CAMCORP, Inc.

Phone: 913-831-0740 ~ Fax: 913-831-9271

www.camcorpinc.com

Symptom

Leaking Oil

Chronic Fuse Blowing or
Circuit Breaking

Overheating

Possible Causes

Failed Oil Seals

End Cover Seams Not Tight

Oil Foaming

Excessive Motor Amperage

Underrated Fuses

Premature Heater Strip
Actuation

Excessive Pressure Ratio

Insufficient Rotor Speed

10

Possible Sources

Foreign Material in Seal Bores
Faulty Installation
Non-spec Oil
Contaminated Oil
Overheated Rotor Shafts

Bolts Loose
Gaskets Torn

Non-spec Oil
Oil Cavities Overfilled

Excessive Pressure Ratio
Excessive Pump Speed
Line Voltage Drop
Air Density Increase
Loose Electrical Connections
Foreign Material in Air Box

Unusually High Ambient
Temperature
Underrated Heater Strips

Clogged Filter Element
Collapsed Inlet Hose
Clogged Dust Vent Filter
Undersized Dust Vent Filter
Clogged Diffusion Pads
Faulty Check Plate
Improperly Installed Check
Plate

Wrong Sheave Set
Wrong Motor Speed
Slipping Belts

Advertising