SECTION 4
OPERATION

Future operating problems can be avoided if proper precautions are observed when the equipment is first put into
service.

Before starting under power, the blower should be turned over by hand to make certain there is not binding or
internal contact.

Each size blower has limits on pressure differential, running speed and discharge temperature which must not be
exceeded. These limits are shown in “Maximum Operating Limitations”, FIGURE 4-1, below.

Operating beyond the specified operating limitations will result in damage to the unit.

It is important that the pressures and temperatures are measured directly at the ports of the blower to avoid error
that may be caused by intervening pipe runs, fittings, etc.

Relief valves must be used to protect against excessive pressure or vacuum conditions. These valves should be
tested at initial startup to be sure they are adjusted to relieve at or below the maximum pressure differential rating
of the blower.

NOTICE

Relief valves should be placed as close as possible to the blower inlet or discharge.

In some instances, pressure may be relieved at a lower point than the blower maximum in order to protect the
motor or the equipment served by the blower.

Discharge temperature switches are recommended to protect against excessive inlet restriction or inlet
temperatures. Check valves in the discharge line on pressure blowers and in the inlet line on vacuum blowers are
recommended to protect the blower from motoring backwards when shut down under load.

LIMITATIONS

For information regarding limitations, refer to FIGURE 4-1, below.

MAXIMUM OPERATING LIMITATIONS

SIZE

RPM

PRESSURE

PSI

VAC

IN HG

DISCHARGE

TEMPERATURE ° F

2LP

5275

7

14

285

2MP

5275

12

15

315

3LP

3600

7

14

260

3MP

3600

12

15

280

3HP

3600

15

16

320

4LP

3600

7

14

260

4MP

3600

10

16

285

4HP

3600

15

16

310

5LP

2850

7

14

260

5MP

2850

13

16

280

5HP

2850

15

16

300

DO NOT EXCEED THESE LIMITS

NOTICE

Blower speed, line losses, elevation, and increased inlet temperatures will affect the
maximum operating limitations.

FIGURE 4-1 – MAXIMUM OPERATING LIMITATIONS