Symptom, Possible causes, Possible sources – CAMCORP Blower Package with M-D Pneumatics Blower User Manual

Page 10

Advertising
background image

CAMCORP, Inc.

Phone: 913-831-0740 ~ Fax: 913-831-9271

www.camcorpinc.com

Symptom

Poor Performance

Possible Causes

Belt Flutter

Restricted Inlet

Down Stream Restriction

Erroneous Pressure or
Vacuum Indication

Air Leakage

Insufficient Rotor Speed

Excessive Rotor Clearances

Change in Conveyed
Material

9

Possible Sources

Insufficient Static Tension
Sheave Misalignment
Sever Torsional Vibration

Clogged Filter Element
Collapsed Inlet Hose

Clogged Dust Filter
Undersized Dust Filter
Faulty Check Plate
Improperly Installed Check
Plate

Loose Gauge Connection
Gauge Movement Damaged
Gauge Inaccurately Calibrated

Improper Relief Valve Setting
Blown Gaskets
Loose Piping Joints

Wrong Sheave Set
Wrong Motor Speed
Slipping Belts

Abrasive Wear of Rotor
Surfaces
Rotor “Lag” Timed

Material More Difficult to
Fluidize
Material of Higher Density
Moisture Content of Material
Too High