13

When removing gear shell from driven gear, it is not necessary to
remove gear lock bolt.
After completing the timing of the lobes bend over lock tabs on
the four gear cap screws.
19. Install gear cover [7] using same method as was used to in-

stall drive cover. (Step 18).

20. Install mounting feet [304] and secure with cap screws and

washers [307 & 80].

21. Prior to putting blower into operation, follow Installation and

Operation instructions. Observe the oil level frequently, dur-
ing the initial hours of operation. A badly installed or dam-
aged oil seal will result in oil loss.

Figure 9.

SPECIAL TOOL DRAWINGS - MODEL 4500/4600

All dimensions shown are in inches.

MODEL 4500/4600

LIP SEAL PRESSING TOOL

MODEL 4500/4600

BEARING INSTALLATION TOOL