Maintenance – CAMCORP Blower Package with M-D Pneumatics Blower User Manual

Page 8

Advertising
background image

7

CAMCORP, Inc.

Phone: 913-831-0740 ~ Fax: 913-831-9271

www.camcorpinc.com

MAINTENANCE

A.

Check oil level daily

B. Refer to the general lubrication guidelines in this manual for recommended

frequency of oil change and type of oil. For more specific information on blower
maintenance and lubrication see the manufacturer’s insert (manual) accompanying
this manual.

C.

Clean the intake or inline filter every 40 hours or more often if dust conditions are
severe. The filter element is washable using luke warm water with mild detergent.

D.

Check the drive belts for tension after the first 24 hours of operations and every 100
hours thereafter. Sheaves and belts should be inspected every 200 hours.

E.

Silencers should be inspected periodically for: 1) being plugged, 2) corrosion, 3) oil
coating (discharge silencers) and for any deterioration.