Overload Operation

The overload indicator light will turn on when the rated
load is exceeded. When the maximum load is reached,
the LED will blink and cut power to the receptacles. To
recover the power, shut down the engine, wait until the
light turns off and restart the generator.

The owner/operator is responsible for all periodic
maintenance.

Complete all scheduled maintenance in a timely manner.
Correct any issue before operating the generator.

Tampering with the factory set governor will void
your warranty.

Engine Maintenance

To prevent accidental starting, remove and ground spark
plug wire before performing any service.

Oil

Change oil when the engine is warm. Refer to the oil
specification to select the proper grade of oil for your
operating environment.
1. Set the generator on top of a work bench or table.
2. Loosen the cover screws and remove the

maintenance cover.

3. Pop up the rubber maintenance plug, from below

the drain bolt.

Spark Plugs

1. Remove the maintenance cover.
2. Remove the spark plug cable from the spark plug.
3. Use the spark plug tool that shipped with your

generator to remove the plug.

4. Remove the spark plug.
5. Inspect the electrode on the plug. It must be clean

and not worn to produce the spark required for
ignition.

6. Make certain the spark plug gap is 0.7 - 0.8 mm

(0.028 - 0.031 in.).

7. Carefully thread the plug into the engine.
8. Use the spark plug tool to firmly install the plug.

9. Attach the spark plug cap to the plug.
10. Reinstall the spark plug access cap, and

maintenance cover.

For service or parts assistance, contact our help
line at

1-877-338-0999

NOTE

Maintenance, replacement, or repair of emission
control devices and systems may be performed
by any non-road engine repair establishment or
individual.

NOTE

Never operate a damaged or defective generator.

WARNING

WARNING

Improper maintenance will void your warranty.

WARNING

Oil Cont’d.

0.7-0.8 mm

0.028-0.031 in.

MAINTENANCE AND STORAGE

Once oil has been added, a visual check should show
oil about 1-2 threads from running out of the fill hole.
If using the dipstick to check oil level, DO NOT screw
in the dipstick while checking.

NOTE

4. Remove the 12 mm drain bolt.
5. Tilt the generator on its side and allow the oil to

drain completely.

6. Add 0.6 qt. (0.6 L) of oil and replace oil fill cap/

dipstick. DO NOT OVERFILL.

7. Reinstall the maintenance cover and tighten the

cover screws.

8. Dispose of used oil at an approved waste

management facility.