Maintenance and storage, Caution, Danger – Champion Power Equipment 75555i User Manual

Page 17: Storage, Generator maintenance

Advertising
background image

REV 75555i-20140110

14

75555i

ENGLISH

Storage

The generator should be started at least once every 14
days and allowed to run for at least 20 minutes. For
longer term storage, please follow these guidelines.

Generator Storage

1. Add a properly formulated fuel stabilizer to the tank.
2. Be sure all appliances are disconnected from the

generator.

3. Run the generator for a few minutes so the treated

fuel cycles through the fuel system and carburetor.

4. Turn the fuel valve to the “Off” position.
5. Let the generator run until fuel starvation has

stopped the engine. This usually takes a few
minutes.

6. The generator needs to cool completely before

cleaning and storage.

7. Remove the spark plug cap, then pull the recoil grip 3

times to drain the gasoline from the carburetor jets.

8. Change the engine oil.
9. Remove the spark plug and pour about a tablespoon

of oil into the cylinder. Crank the engine slowly to
distribute the oil and lubricate the cylinder.

10. Reattach the spark plug.
11. Store the unit in a clean, dry place out of direct

sunlight.

MAINTENANCE AND STORAGE

Generator Maintenance

Make certain that the generator is kept clean and stored
properly. Only operate the unit on a flat, level surface in
a clean, dry operating environment. DO NOT expose the
unit to extreme conditions, excessive dust, dirt, moisture
or corrosive vapours.

Use a damp cloth to clean exterior surfaces of the generator.
Use a soft bristle brush to remove dirt and oil.
Use an air compressor (25 PSI) to clear dirt and debris
from the generator.
Inspect all air vents and cooling slots to ensure that they
are clean and unobstructed.

DO NOT use a garden hose to clean the generator.

Water can enter the generator through the cooling
slots and damage the generator windings.

CAUTION

Generator exhaust contains odourless and
colourless carbon monoxide gas.

To avoid accidental or unintended ignition of your
generator during periods of storage, the following
precautions should be followed:

– When

storing the generator for short or extended

periods of time make sure that the Engine
Switch and the Fuel Valve are set in the

OFF

position.

DANGER

Advertising