15

REV 75555i-20140110

ENGLISH

75555i

Oil

Use 10W-30 automotive oil.
Oil capacity is 0.6 qt. (0.6 L).
DO NOT OVERFILL
Please reference the following chart for recommended
oil types for use in the generator.

Fuel

Fuel capacity is 6 L (1.6 gal.). Use regular unleaded
gasoline with a minimum octane rating of 85 and an
ethanol content of less than 10% by volume.

SPECIFICATIONS

Maintenance Valve Clearance

– Intake: 0.06 - 0.12 mm (0.002 - 0.005 in.)

– Exhaust: 0.08 - 0.14 mm (0.003 - 0.006 in.)
Note: Tech bulletin regarding the valve adjustment
procedure is on www.championpowerequipment.com.

Generator Specifications

– Model

75555i

– Rated Load

2800 Watts

– Maximum Load

3100 Watts

– AC Load

120 V

– Phase

Single

– Frequency

60 Hz

– Fuel Capacity

6 L (1.6 gal.)

– Gross Weight

43 kg (94.8 lb.)

– Net Weight

37.4 kg (82.5 lb.)

– Height

18.3 in. (46.4 cm)

– Width

17.3 in. (44 cm)

– Length

22.4 in. (57 cm)

Engine Specifications

– Model

YF166FD-33

– Displacement

171cc

– Type

4-Stroke OHV

– Start Type

Recoil

Spark Plugs

OEM spark plug: NHSP F6RTC
Replacement spark plug: NGK BPR6ES or equivalent
Make certain the spark plug gap is 0.7 - 0.8 mm or
(0.028 - 0.031 in.).

IC Warning

This device complies with Industry Canada licence-
exempt RSS standard(s).
Operation is subject to the following two conditions
(1) This device may not cause interference, and
(2) This device must accept any interference, including
interference that may cause undesired operation of the
device.

An Important Message About Temperature

Your Champion Power Equipment product is designed
and rated for continuous operation at ambient
temperatures up to 40°C (104°F). When your product is
needed your product may be operated at temperatures
ranging from -15°C (5°F) to 50°C (122°F) for short
periods. If the product is exposed to temperatures
outside this range during storage, it should be brought
back within this range before operation. In any event,
the product must always be operated outdoors, in a
well-ventilated area and away from doors, windows and
other vents.