Chicago Electric 97677 User Manual

Page 6

Advertising
background image

Page 6

SKU 97677

For technical questions, please call 1-800-444-3353.

of electric shock.

(See 3-Prong Plug

and Outlet.)
The grounding prong in the plug is

2.

connected through the green wire

inside the cord to the grounding

system in the tool. The green wire

in the cord must be the only wire

connected to the tool’s grounding

system and must never be attached

to an electrically “live” terminal.

(See

3-Prong Plug and Outlet.)
The tool must be plugged into an

3.

appropriate outlet, properly installed

and grounded in accordance with all

codes and ordinances. The plug and

outlet should look like those in the

preceding illustration.

(See 3-Prong

Plug and Outlet.)

Double Insulated Tools: Tools

with Two Prong Plugs

Outlets for 2-Prong Plug

1. Tools marked “Double Insulated”

do not require grounding. They

have a special double insulation

system which satisfies OSHA

requirements and complies with the

applicable standards of Underwriters

Laboratories, Inc., the Canadian

Standard Association, and the

National Electrical Code.

(See

Outlets for 2-Prong Plug.)
Double insulated tools may be used

2.

in either of the 120 volt outlets shown

in the preceding illustration.

(See

Outlets for 2-Prong Plug.)

Extension Cords

Grounded

1.

tools require a three wire

extension cord. Double insulated

tools can use either a two or three

wire extension cord.
As the distance from the supply

2.

outlet increases, you must use a

heavier gauge extension cord. Using

extension cords with inadequately

sized wire causes a serious drop in

voltage, resulting in loss of power and

possible tool damage.

(See Table A, next page.)
The smaller the gauge number of the

3.

wire, the greater the capacity of the

cord. For example, a 14 gauge cord

can carry a higher current than a 16

gauge cord.

(See Table A.)

When using more than one extension

4.

cord to make up the total length,

make sure each cord contains at

least the minimum wire size required.

(See Table A.)
If you are using one extension cord

5.

for more than one tool, add the

nameplate

amperes and use the sum

to determine the required minimum

cord size.

(See Table A.)

If you are using an extension cord

6.

outdoors, make sure it is marked with

the suffix “W-A” (“W” in Canada) to

indicate it is acceptable for outdoor

use.
Make sure the extension cord is

7.

properly wired and in good electrical

condition. Always replace a damaged

extension cord or have it repaired by

a qualified electrician before using it.