Connecting to refrigerator – Whirlpool EB21DKXDB01 User Manual

Page 13

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

U S I N G Y O U R R E F R I G E R A T O R

5. Fasten shut-off valve to cold water pipe with pipe

clamp. Be sure outlet end is solidly in the Vi-inch
drilled hole in the water pipe and that washer is

under the pipe clamp. Tighten packing nut. Tighten

the pipe clamp screws carefully and evenly so
washer makes a watertight seal. Do not overtighten
or you may crush the copper tubing, especially if soft

(coiled) copper tubing is used. Now you are ready to
connect the copper tubing.

6. Slip compression sleeve and compression nut on

copper tubing as shown in diagram. Insert end of
tubing into outlet end squarely as far as it will go.

Screw compression nut onto outlet end with adjust­
able wrench. Do not overtighten. Turn ON main
water supply and flush out tubing until water is clear.
Turn OFF shut-off valve on the water pipe. Coil
copper tubing.

Connecting to refrigerator

NOTE: The first step for connecting the water line to
your refrigerator is different depending on the type of

water valve provided with your refrigerator. See the
diagrams at right to determine the style of valve you

have. (On kit models, assemble water valve to refrig­

erator per kit instructions.)

1. For style #1, disconnect the tube clamp on the back

of the product and insert the copper tubing through
the clamp, as shown at the right. Remove the tape
label from the valve inlet and insert copper tubing

until it bottoms out (approximately % inch). Tighten
nut by hand as much as possible; then turn the nut
an additional Vz turn using a wrench. Do not over­

tighten. Re-attach the tube clamp and tube to the

back of the cabinet. Skip to step 2.

For style #2, disconnect the tube clamp on the
back of the product and insert copper tubing through
the clamp as shown at the right. Attach the copper

tube to the valve inlet using a compression nut and

sleeve as shown. Tighten the compression nut. Do
not overtighten. Re-attach the tube clamp and tube

to the back of the cabinet. Move to step 2.

2. Turn shut-off valve ON. CHECK FOR LEAKS.

TIGHTEN ANY CONNECTIONS (INCLUDING
CONNECTIONS AT THE VALVE) OR NUTS
THAT LEAK.

3. The ice maker is equipped with a built-in water

strainer. If local water conditions require periodic
cleaning or a well is your source of water supply, a
second water strainer should be installed in the Vi-
inch water line. Obtain a water strainer from your
nearest appliance dealer. Install at either tube
connection.

4. Reconnect electrical supply to refrigerator.

Style #1 valve

Style #2 valve

13

Advertising