Recommended grounding method, Temporary grounding method, Electrical requirements – Whirlpool AD0402XS0 User Manual

Page 4

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Electrical Requirements

OBSERVE ALL GOVERNING CODES AND ORDINANCES.
Electrical ground is required on this appliance.

A115 volt, 60 Hz., AC only, 15 or 20 ampere fused electrical supply is required, (Time
delay fuse or circuit breaker is recommended.) It is recommended that a separate circuit

serving only this appliance be provided. Do not use an extension cord.

DO NOT UNDER ANY CIRCUMSTANCES, REMOVE THE POWER SUPPLY CORD GROUND PRONG.

RECOMMENDED GROUNDING METHOD

For your personal safety, this appliance must be

grounded. This appliance is equipped with a
power supply cord having a 3-prong grounding
plug. To minimize possible shock hazard, the cord
must be plugged into a mating 3-prong ground­
ing type wall receptacle, grounded in accord­
ance with the National Electrical Code and local

codes and ordinances. If a mating wall recepta­
cle is not available, it is the personal responsibility
and obligation of the customerto have a properly
grounded 3-prong wall receptacle installed by a
qualified electrician.

TEMPORARY GROUNDING METHOD

If changing and properly grounding the wall re­

ceptacle is impossible and where local codes
permit (consultyourelectrical inspector), a tempo­
rary adaptor may be plugged into the existing 2-
prong wall receptacle to mate with the 3-prong
power supply cord THIS HOWEVER, IS NOT
RECOMMENDED.

If this is done, you must connect the grounding

eyelet on the ada pter to the wall receptacle cover
plate screw and from this same screw, you must
connect a separate copper ground wire (#14 mini­
mum) to

a

grounded cold water pipe.* Do not

ground to a gas supply pipe. Do not connect to
electrical supply until appliance is perma­
nently grounded.

ELECTRICALLY
GROUNDED METAL
COLD-WATER PIPE
(REMOVE PAINT, ETC.)

GROUND ASSEMBLY
(AnACH TO GROUNDED
METAL COLD-WATER PIPE)

3-PRONG
GROUNDING
PLUG

ADAPTER

GROUND PRONG

POWER SUPPLY CORD

WALL
RECEPTACLE

*Cold water pipe must have metal continuity to electrical ground and not be interrupted
by plastic, rubber or other electrically insulating connectors (including water meter or
pump) without adding a jumper wire at these connections.

Advertising