Dehumidifier DE-ICER control

^he 48,40 and 30 pint models have a DE-ICER control this feature allows you to
operate the unit in room temperatures below 65 F (18,3 C) Without this DE-ICER control,
the unifs evaporator coll would form frost that could prevent proper operation.

'he DE-ICER control senses frost build-up on the evaporator coils. When frost build-up is

sensed it automatically shuts off the compressor, but allows the fan to continue running.

The fan draws air across the coil which melts the frost. When the coil is defrosted, the

DE-ICER control automatically restarts the compressor ana resumes dehumidifying.

these units will not operate properly in room temperatures below 50 F (10 C],

If you need serviee or assistanee, we suggest

is the dehumidifier correctly plugged into a live
circuit with the proper voltage?
Is the Humidistat Control set to a position other

than UNIT OFF? Try a dryer setting.

• Have you checked the main fuse or circuit

breaker box?

• If a 48, 40 or 30 pint model, is the temperature

below 50 F (10 C)? The fan should run, but the unit

will not dehumidify.

If unit blows fuses or trips circuit breakers:

• Are correct time-delay fuses being used in the

main fuse box?

1. Before calling for assistance...

Performance problems often result from little things
you can find and fix yourself without tools of any
kind.

If unit won’t operate:

• is an extension cord being used? Do not use an

extension cord.

• Are the coils iced or clogged with lint?

If unit ices up:

• Is humidity too iow?
• Is room temperature below 65 F(18.3 C)'?’Coil will

become iced over at low temperatures, except

the 48,40 and 30 pint models which will operate
down to 50 F (10 C).

If water collects on the floor:

• Is unit reasonably level?
• Is hose or drain clogged or kinked?
• Is the water pan overflowing? Pan must be prop­

erly positioned.

Special dehumidifier needs:

• Annual inspection: Clean coils, inspect drain

and hoses; if necessary, oil the fan motor.

• Moving: When moving, keep the unit in an up­

right position.

Remember...Please include the model and serial
number of your appliance when requesting serv­
ice. Also, retain your sales slip and warranty to ver­
ify your warranty status. Learn the benefits of using

TECH-CARE" service for maintaining the quality

originally built into your WHIRLPOOL appliance.

2. If you need assistance"^...

Call Whirlpool COOL-LINE" service assistance
telephone number. Dial free from anywhere in
the U.S.:

1-800-253-1301

and talk with one of our trained consultants. The
consultant can instruct you in how to obtain satis­
factory operation from your appliance or, if serv­
ice is necessary, recommend a qualified service
company in your area.