U S I N G Y O U R R E F R I G E R A T O R

Exterior moisture control

The Exterior Moisture Control operates

electric heaters around the door openings.
These heaters help keep moisture from

forming on the outside of the refrigerator

cabinet.
• Use the OFF setting when humidity is low.
• Use the ON setting if moisture forms on

the outside of the refrigerator cabinet.

Changing the control settings

• Adjust the Refrigerator Control first.
• Wait at least 24 hours between adjust­

ments.

• Then adjust the Freezer Control if needed.

If you need to adjust temperatures in

refrigerator or freezer, use the settings listed
in the chart below as a guide. If you have

questions, call our Consumer Assistance
Center number. (See page 27.)

CONDITION:

REASON:

RECOMMENDED

CONTROL SETTINGS:

Refrigerator

• Door opened often

Refrigerator

4

section
too warm

• Large amount of food added
• Room temperature too warm

Freezer

A

Freezer

• Door opened often

Refrigerator

3

section

too warm

• Large amount of food added

• Very cold room temperature

(can’t cycle often enough)

Freezer

C

Refrigerator

• Controls not set correctly

Refrigerator

2

section
too cold

for your conditions

Freezer

B

Ice not

• Heavy ice usage

Refrigerator

3

made fast

enough

• Very cold room temperature

(can’t cycle often enough)

Freezer

C

Both

• Door opened often

Refrigerator

4

sections
too warm

• Large amount of food added
• Very warm or very cold room

temperatures

Freezer

B