B preparing for installation, Disconnecting gas, Removing lint from wall exhaust opening – GE 500A436P006 User Manual

Page 2: E] gas requirements, Installation instructions, Connectors

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

IViinimum Clearance Other Than Alcove or Closet installation

Minimum clearance to combustible surfaces and for air opening are: 0 in. clearance both sides and 1 in. rear. Consideration
must be given to provide adequate clearance for proper operation and sendee.

installation instructions

[B PREPARING FOR INSTALLATION

OF NEW DRYER

TIP: Install your dryer before installing your washer.
This will allow better access when installing dryer exhaust.

DISCONNECTING GAS

TURN GAS
SHUT-OFF VALVE
TO THE OFF

POSITION.

V

DISCONNECT AND DISCARD OLD
FLEXIBLE GAS CONNECTOR AND
OLD TRANSITION DUCTING
MATERIAL. REPLACE WITH NEW

CSA(AGA) APPROVED FLEXIBLE
GAS LINE CONNECTOR AND UL
APPROVED TRANSITION DUCT.

A

w

ARNING - NEVER REUSE OLD

FLEXIBLE

CONNECTORS.

The use of old flexible connectors can cause leaks and
personal injury. Always use new flexible connectors when
installing gas appliances.

REMOVING LINT FROM WALL

EXHAUST OPENING

• Remove and discard existing plastic or metal foil

transition duct and replace with UL listed transition
duct.

INTERNAL
OPENING

CHECK THAT EXHAUST
HOOD DAMPER OPENS
AND CLOSES FREELY.

TILTTHE DRYER SIDEWAYS
AND REMOVE THE FOAM
SHIPPING PADS BY

PULLING AT THE SIDES

AND BREAKING THEM
AWAY FROM THE DRYER

LEGS. BE SURE TO
REMOVE ALL OF THE
FOAM PIECES AROUND

THE LEGS.

E] GAS REQUIREMENTS

A

WARNING

• Installation must conforai to local codes and ordinances,

or in their absence, the NATIONAL FUEL GAS CODE,

ANSI Z223.

• This gas dryer is equipped with a Valve & Burner Assem­

bly for use only with natural gas. Using conversion kit

WE2 5X0217, your local service organization can convert

this dryer for use with propane (LP) gas. AI.L CONVER­
SIONS MUST BE MADE BY PROPERIY TRAINED

AND QUALIFIED PERSONNEL AND IN ACCOR­

DANCE WITH LOCAL CODES AND ORDINANCE
REQUIREMENTS.

• The dryer must be disconnected from the gas supply

piping system during any pressure testing of that system
at a test pressure in excess of 0.5 PSI (3.4 KPa).

• The dryer must be isolated from the gas supply piping

system by closing the equipment shut-off valve during
any pressure testing of the gas supply piping of test
pressure equal to or less than 0.5 PSI (.3.4 KPa).

DRYER

GAS SUPPLY CONNECTION

the distance between cabinet

bottom to floor.

GAS SUPPLY

• A I/8-in. National Pipe Taper thread plugged tapping,

accessible for test gauge connection, must be installed
inrmediately upstream of the gas supply connection to
the dryer. Contact your local gas utility should you have
questions on the installation of the plugged tapping.

• Supply line is to be I/2-in. rigid pipe and equipped with

an accessible shut-off within 6 ft. of, and in the same

room with the dryer.

• Use pipe thread sealer cornpoundor Teflon tape

appropr iate for naturalor LP gas.

• You must use with this dryer a flexible metal connector

listed connector ANSI Z2I.24 / CSA 6.10. The length of
the connect shall not exceed .3 ft.

• Connect flexible metal connector to dryer and gas sirpply.
• Open shut-off valve.

Advertising