M exhaust connection, 8 leveling dryer, Instailatiori instructions – GE 500A436P006 User Manual

Page 5: Exhaust connection

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

instailatiori instructions

m

EXHAUST CONNECTION

A

WARNING - TO REDUCE THE RISK

OF FIRE OR PERSONAL INJURY:

® This clothes diyer must be exhausted to the outdoors.
® Use only 4” rigid metal ducting for the home exhaust

duct.

® Use only 4” rigid metal or ULdisted flexible metal

(semi-rigid or foil-type) duct to connect the dryer to the

home exhaust duct. It must be installed in accordance

with the instructions found in “Connecting The Dry'er

To House Vent” on page 6 of this manual.

® Do not terminate exhaust in a chimney, a wall, a

ceiling, gas vent, crawl space, attic, under an enclosed
floor, or in any other concealed space of a building.
The accumulated lint could create a fire hazard.

® Never temiinate the exhaust into a common duct with

a kitchen exhaust system. A combination of grease and
lint creates a potential fire hazard.

® Do not use duct longer than specified in the exhaust

length table. Longer ducts can accumulate lint,
creating a potential fire hazard.

® Never install a screen in or over the exhaust duct. This

will cause lint to accumulate, creating a potential fire

hazard.

® Do not assemble ductwork with any fasteners that

extend into the duct. These fasteners can accumulate
lint, creating a potential fire hazard.

® Do not obstruct incoming or exhausted air.
® Provide an access for inspection and cleaning of the

exhaust system, especially at turns and joints. Exhaust
system shall be inspected and cleaned at least once a year.

THIS DRYER COMES READY FOR REAR

EXHAUSTING. IF SPACE IS LIMITED, USE

THE INSTRUCTIONS IN SECTION 9 TO

EXHAUST DIRECTLY FROM THE SIDES OR
BOTTOM OF THE CABINET.

STANDARD REAR EXHAUST

(Vented above floor level)

NOTE: ELBOWS WILL PREVENT DUCT
KINKING AND COLLAPSING.

STANDARD REAR EXHAUST

(Vented at floor level)

FOR STRAIGHT LINE INSTALLATION, CONNECT THE DRYER EXHAUST TO

THE EXTERNAL EXHAUST HOOD USING DUCT TAPE OR CLAMP.

NOTE: WE STRONGLY RECOMMEND SOLID METAL EXHAUST DUCTING.
HOWEVER, IF FLEXIBLE DUCTING IS USED IT

MUST

BE UL-LISTED METAL

NOT

PLASTIC.

8 LEVELING DRYER

FINAL LOCATION AND ADJUST THE 4 LEVELING
LEGS TO MATCH THE HEIGHT OF YOUR WASHER.

ADJUST THE 2 ANTI-TIP LEGS TO CONTACT
THE FLOOR.

Advertising