installation instructions

3J RECOIMiMECTiiMG GAS

Listed connector ANSI Z21.24 / CSA 6.10

Note: The connector and fittings are designed for use only

on the original installation and are not to be reused for

another appliance or at another location. Keep flare end of

adaptor free of grease, oil and thread sealant.

Caution: Use adapters as shown. Connector nuts must not

be connected directly to pipe threads.

TO THE ADAPTER AND

DRYER GAS INLET.

4 LEAKIEST

A

WARNING - NEVER USE AN OPEN

FLAME TO TEST FOR GAS LEAKS.

OPEN

GAS VALVE

Check all connections for leaks with soapy solution or equivalent.

Apply soap solution.

Leak test solution must not contain ammo­

nia which could cause damage to the brass fittings.

If leaks are

found, close valve, retighten the joint, and repeat the soap test.