background image

12

Dutchwest

7001219

Stove Installed

Stove in

Stove Installed

Stove in

Parallel to Wall

Corner

Paralle to Wall

Corner

Side

Rear

Corners

Side

Rear

Corners

No heat shields

(A) 22”

(B) 24”

(C) 18”

(D) 12”

(E) 14”

(F) 10”

(559 mm)

(610 mm)

(457 mm)

(305 mm)

(356 mm)

(254 mm)

Rear exit, rear h.s.

(G) 22”

(H) 14”

n/a

(I) 12”

(J) 12”

n/a

(559 mm)

(356 mm)

(305 mm)

(305 mm)

Top exit

1

, rear h.s.

(K) 22”

(L) 24”

(M) 18”

(N) 12”

(O) 14”

(P) 10”

single-wall connector

(559 mm)

(610 mm)

(457 mm)

(305 mm)

(356 mm)

(254 mm)

No connector h.s.
Top exit

1,2

, rear h.s.

(K) 22”

(L) 14”

(M) 15”

(N) 12”

(O) 12”

(P) 8”

single-wall connector

(559 mm)

(356 mm)

(381 mm)

(305 mm)

(305 mm)

(203 mm)

with connector h.s.
Top exit

1

, rear h.s.

(K) 22”

(L) 15”

(M) 19”

(N) 12”

(O) 11”

(P) 8”

double-wall connector

(559 mm)

(381 mm)

(483 mm)

(305 mm)

(279 mm)

(203 mm)


Single-wall connector

19”

9”

no connector h.s.

(483 mm)

(229 mm)

Single-wall

2

connector

9”

7”

with connector h.s.

(229 mm)

(178 mm)

Double-wall connector

14”

6”

(356 mm)

(152 mm)

All Installation

48” (1219 mm)

1. Shielding for a top exit stove must include a shield insert to protect the area behind the flue collar.
2. Chimney connector heat shields must extend exactly 24” (610 mm) above the flue collar of the stove.
3. All installations venting straight up to a factory built chimney require a 24” (610 mm) diameter or square ceiling heat shield. The

ceiling heat shield should be 24 gauge sheet metal or equivalent mounted on 1” (25 mm) noncombustible spacers 1” (25 mm) below
ceiling.

4. Chimney connector heat shields must extend to within 1” (25 mm) or less of the ceiling heat shield for installations venting straight up

to a factory-built chimney. In top exit installations using an elbow to vent to the rear, the chimney connector must be shielded over the
entire vertical length.

5. If a single-wall oval-to-round adapter is used, a shield must be used to protect combustibles to the rear of the adapter.

Stove and Chimney Connector Clearance Charts

Unprotected Surfaces

Protected Surfaces

Stove Clearance

Chimney Connector Clearance

Front Clearance to Combustibles

Advertising