BYPASS VALVES

Bypass valve(s) should always remain In soft water
service position. Position in “bypass” only if needed for
softener repairs.

SINGLE BYPASS

pull stem

outward for

service

push

inward for

bypass

Inches

cm

A

Salt Tank Height

40-1/4

102.2

B

Resin Tank Diameter
(nominal)

8

20.3

C

Resin Tank Height (nominal)

40

101.6

D

Inlet-Outlet Height

41-1/2

105.4

E

Overall Height

47-3/4

121.3

Fi

Length

19-3/4

50.2

F2

Width

16-1/2

41.9

-

Distance between inlet-outlet
centerlines

3-3/8

8.6

Bypass

valve

Inlet

valve

FIG. 44

MODEL NO. 625.383060 - TIMER CODE S 25

WATER SUPPOr TO WATER SOFTENER

Minimum water system flow (gpm)

3

Minimum-maximum water pressure (psi)

20 - 125

Minimum-maximum water temperature (°F)

40 - 120

Maximum water hardness (gpg)

95

Maximum “clear water” iron (ppm)*

7

SALT FOR WATER SOFTENER

Type of salt needed

nugget or pellet

Alternate type of salt

pure, evaporated, compacted

water softener salt

gpm = gallons per minute gpg = grains per gallon

psi = pounds per square inch ppm = parts per million

^ Capacity to remove clear water iron is substantiated by WQA test data. State of Wisconsin requires

additional treatment if water supply contains greater than 5 ppm clear water iron.

Questions? Call The Kenmore Water Line 1-800-426-9345