SECTION 5

j jjj j jj

1

SERVICE TECH. INFORMATION

A. TROUBLESHOOTING

AUTOMATIC ELECTRONIC DIAGNOSTICS
The faceplate timer (PWA) computer has a self­
diagnostic function for the electrical system, except
for input power and water meter. The computer

monitors electronic components

and circuits for correct opera­
tion. If a malfunction occurs, an

error code appears in the face­

plate display.

£VEIL£VEL

в

7

6

Ё г г З

4

5

2

The chart below shows the error codes that could

appear, and the possible defects for each code.

While an error code appears in the display, all face

plate buttons are inoperable except the SELECT but­
ton. SELECT remains operational so the service per­
son can make the MANUAL INITIATED ELEC­
TRONIC DIAGNOSTICS (below) to further isolate

the defect, and check the water meter.

CODE

POSSIBLE DEFECT

MOST LIKELY

^ LESS LIKELY

Erri, ЕггЗ,
Err4

motor inoperative / wiring harness or connection to switch / position switch / vaive defect causing
high torque

Err5

faceplate timer (PWA)

PROCEDURE FOR REMOVING ERROR CODE FROM FACEPLATE:

1. Unplug transformer 2. Correct defect 3. Plug

in transformer 4. Wait for 6 minutes. The error code will return if the defect was not corrected.

MANUAL INITIATED ELECTRONICS
DIAGNOSTICS

To enter diagnostics...

- - from a error code display, press the SELECT 1

button.

--from a time display, press and hold the SE­
LECT 1 button for 3 seconds.

You will see one of the following displays. AE of the
displays show what position the valve is in, if the
turbine is operating, and the position switch open or
closed status.

valve position indicabx

I

L!

i ^ 4

number of days

since the last

^regeneration

. water meter

turbine count

VALVE IN SERVICE

POSITION

position switch indicator

(open)

valve poelUon mdicator

UHI uw

тшгяемлмша

MJ

Y 033-

«Wl »

\ FLOW HATE

_ minutes of Ml

cycle remaining

- water meter

turbine count

VALVE IN A RECHARGE
POSmON (FILL. IN THIS
EXAMPLE)

position switch Indicator

(open)

valve position indicc№r
(Fill and Brine Dashing)

position switch Indicaur

(dosed)

minutes of biinlng time

(begins to count down

when valve reaches

brining position) VALVE ROTATING

FROM 1 RECHARGE
POSITION TO
ANOTHEB (FROM
FILL TO BRINING IN
THIS EXAMPLE)

POSITION SWITCH STATUS: With the valve in ser­
vice, or any of the recharge cycles, the switch indica­
tor win show open . While the valve is rotating

from 1 position to another, the indicator will show
the switch closed

. A defect is probable if indica­

tions vary from this pattern.

WATER METER TURBINE: With soft water in use,
the turbine flow rate display continually repeats a
000 to 140 count for each gallon of water passing
through the turbine. The display wrli remain a

steady.. .000 if soft water is not in use (open a nearby
soft water faucet to check).

If you don't get a reading in the display, with facuet

open, puU the sensor from the valve outlet port.
Pass a small magnet back and forth in front of the
sensor. You should get a reading in the display. If
you get a reading, unhook the in and out plumbing
and check the turbine for binding.

5 - 2