Troubleshooting Guide (cont’d)

HIGH

TEMPERATURE

SHUT

OFF

SYSTEM

(cont’d)

* Remove the two screws securing the access pane! and remove

panel

* Remove the insulation block to expose tàe opening.

* Reset the high limit by pushing in the red button marked

‘^BESET’’-

■R6SET BUTTON

Replace the insulation block so that it completely covers the
thermostat and element

Replace the access panel.

Turn "OISI" electric power to the water heater.

__________ A

CAUTION__________ _______

If the high limit must be reset again, call Sears Service
Department to find out why the high limit turned “OPF*’
the electric power.

NOT ENOUGH OR NO HOT WATER

In a new instalkrioa, the water heater may not be properly

connected. Malce sure the cold water supply valve is open.

Review and check piping installation. Make sure that the
cold water line is connected to the cold water inlet to the

water heater and the hot water line to the hoc water outlet

on the water heater..

Make sure the electrical supply to your water hearer is

“ON”.

Check for loose or blown fuses in your water heater circuit.

Circuit breaiters wealtcn with age and may not handle rheir
raced load and should be replaced,

Malce certain the disconnect switch, if used, is tn the "ON"

position-

Check to see the electric service to your house has not been

interrupted. If this is the case, contact the electric company,

Are the thermostats set to the desired temperature? See

“Temperature RegubciojT section.

If you had experienced very hot water and now no hot

water, the problem may be due to the high temperature
shut off system. See “High Temperature Shut Off System”
in the “Troubleshooting” section

During very cold weather, the incoming water will also be

colder and it will require a longer time to become heated.

The hot water usage may exceed the capacity of the water

heater. If so, wait for water heater to recover after abnormal
demand. Also examine pipes and faucets for possible water
leaks,

If you can not determine the problem, then call the Sears

Service Department,

Adjust the thermostat to a lower setting. See die “Temperature

Reguktion” section..

23