Step 6 - connect tubes – Kenmore 625.38156 User Manual

Page 14

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

step 6 - Connect Tubes

HOW TO CUT AND CONNECT THE TUBES

Your Reverse Osmosis Water System includes push-in
fittings for quick tubing connection. Review the follow­
ing instructions before connecting the tubes in the next

step.

Cut tubes to length

1. Use a sharp cutter or knife to cut the end of tubing.

Always cut the tubing square. See Figure 17.

2. Inspect the end (about 1") of the tubing to be sure

there are no nicks, scratches or other rough spots. If
needed, cut the tubing again. See Figure 17.

NOTE:

Tubing lengths should allow for the removal of

the assembly from the hanger washers for servicing. If
tubing lengths are shortened for neater appearance, it
may be necessary to keep the assembly on the hanger
washers for service.

Connect tubes

NOTE: Remove protective foam plugs before connect­
ing tubes (See Fig. 16). Discard foam plugs.

1. Push tubing through collet, until it engages the o-ring.

See Figure 18A. Continue pushing until the tube bot­
toms out against the back of the fitting. See Figure 18B.
A common mistake is to stop pushing when the tube
engages the o-ring. This will lead to future leaks.
When a 1/4" tube is fully engaged, 11/16" of the tube

has entered the fitting. When a 3/8" tube is fully
engaged, 3/4" of the tube has entered the fitting. See
Figures 18A & 18B.

2. If using tubing other than tubing supplied with the

system, be sure it is of high quality, exact size and
roundness with a smooth surface.

To Disconnect Tubes

1. Push the collet inward with a finger tip. See Figure 20.

2. Continue holding collet inward while pulling the tub­

ing out. See Figure 20.

Push In Fitting

Foam Plug

Remove and Discard Foam Plugs

Figure 16

Push In Fitting

Tube,

A

Y//aiim4

Jl

U / ,

Cut tubing square with end of tubing round,

smooth, with no cuts, nicks or flat spots.

Tube Correctly Cut

Figure 17

Collet

O-Ring

Tube Partially Engaged With Fitting

Figure 18A

(

Collet

/

O-Rlng

A

Tube Fully Engaged With Fitting

Figure18B

Fitting

O-Ring Seal

Collet

Collet and O-Ring

Figure 19

Collet (Depre.s.s to

Figure 20

Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com

14