Change collet and o-ring, Maintenance – Kenmore 625.38156 User Manual

Page 21

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Maintenance

FLOW CONTROL

The flow control is vital for proper operation of the
Reverse Osmosis membrane cartridge. See Figure 26. The
flow control, located in the red tube at the system hous­
ing, keeps water flowing through the membrane at the
required rate. This is to ensure the system produces the
best quality product water.

Periodically check the flow control assembly to be sure
the small hole through it is clean and unrestricted.

If the flow control assembly requires service, review the
exploded view in Figure 26. Assemble and disassemble
as shown.

Flow Control Insert

1/4" Red Tubing

Figure 26

CHANGE COLLET AND O-RING

1. Remove the collet and o-ring from the fitting with a

small screwdriver. Be careful not to scratch the inter­

nal walls of the collet port. See Figures 27 & 28.

2. Clean collet port, lubricate and insert the o-ring seal

into the bottom of the port. See Figures 27 & 28.

3. Push the collet inward until it locks in place. See

Figures 27 & 28.

Push o-ring seal into bottom of

port then follow with collet.

Fitting

O-Ring Seal

Collet

Change collet and o-ring

Collet (depress to
remove tubing)

'\

Tubing

Disconnect Tubing

Figure 27

Figure 28

CHANGE

BATTERY

To change battery, complete the following steps.

1. Loosen the screw on the right side of the faucet base.

See Figure 29.

2. Press the battery housing upwards from the front

faucet base until it releases from the faucet base. See
Figure 29.

3. Replace the battery (Maxell CR 2032 or equivalent).

Place battery into the holder with the positive (+) side
facing the back of the holder.

4. When the battery is first replaced it will flash six times

and turn off. This indicates the battery is fully
charged. After the six flashes the timer enters the 6
month time cycle. If it repeatedly flashes just two
times, it is not a fully charged battery.

5. Re-install the battery housing and firmly tighten the

mounting screw. See Figure 29.

Screw

Figure 29

Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com