Service and Adjustment (cont’d)

Draining

The water heater should be drained if being shut down during
freezing temperatures. Also periodic draining and cleaning of
sediment from the tank may be necessary.

• Turn the gas control knob to the “OFF” position.
• CLOSE the cold water inlet valve to the water heater.
• OPEN a nearby hot water faucet and leave open to allow for

draining.

• Connect a hose to the drain valve and terminate to an

adequate drain.

• OPEN the water heater drain valve to allow for tank

draining.
NOTE: If the water heater is ^ing to be shut down and
drained for an extended period, the drain valve should be
left open with hose conn«:ted allowing water to terminate
to an adequate drain.

• Close the drain valve,
• Follow instructions in the “Filling The Water Heater”

section.

• Follow the lighting instructions in the “Lighting” section to

restart the water heater.

Temperature-Pressure Relief
Valve Operation

The temperature-pressure relief valve must be manually operated

at least once a year.

ТЕМ PERATURE-PRESSURE

Failure to install and maintain a new properly listed tempera­
ture-pressure relief valve will release the manufacturer from any
claim which might result from excessive temperature or pressure.

AWARNING

If rite temperature-pressure relief valve on the appliance

weeps or disdiarges periodically, this may be due to thermal

expansion. Your water heater may have a check valve
in^led in the water line or a water meter with a check
valve. Consult the Sears Service Center for further informa­
tion. Do not plug the temperature-pressure relief valve.

AWARNING

When checking Ihe temperatureqjressure rdief valve opera­
tion, make sure that (I) no one is in front of or around the

outlet of the tempera№re-pressure relief valve discharge line,
and (2) that the water manually discharged will not cause any
property dami^ because the water may be extremely hot
if after manually operating the valve, it fails to completely
reset and continues to release water, immediately close the
cold water inlet to the water heater, follow the draining

instructions, and replace the temperature-pressure relief

valve with a new one.

Drain Valve Washer
Replacement

NOTE: For replacement “se a i i VI" thick washer

available at your nearest hardware store. For ordcrii^ replace­
ment vrashers, refer to the “Parte Order List” section.

Turn “OFF” gas supply to water heater.

Follow “Draining" instructions.

• Turning counter clockwise, remove the hex cap below the

screw handle.

Remove the washer and put the new one in place.

Screw the handle and cap assembly back into the drain valve
and reti^ten using a wrench. DO NOT OVERTIGHTEN.

Follow instructions in the “Filling The Water Heater”
section.

Check for leaks.

Follow the lighting instrnctions in the “Lighting” section to
restart the water heater.

Vacuum around base of water heater for dust, dirt, and lint on a

regular basis.

______________ AWARNING"________________ ^

INSTALLED IN SUITABLE AREA: To insure sufficient vetitih
lation and combustion air supply, proper clearances fiwn the

water heater must be maintained. See “Facts to Consider

About the Location” section. Combustible materials such as
clothing, denting materials, or flammable liquids, etc.
not be placed against or adjacent to the water heater which
can cause afire.

Service

Before calling for repair service, read the “Start Up Conditions”
and “Operational Conditions” found in the Troubleshooting
Guide of this manual.
If a condition persists or you are uncertain about the operation
of the water heater, let a qualified person check it out.