AWARNING

The mter heater with draft hood installed must be prop­
erly vented to a chimney which terminates outdoors.

Never operate the water heater unless it is vented to the
outdoors and has adequate air supply to avoid risks of
improper operation, explosion or asphyxiation.

AWARNING

Minimum clearances between the water heater and com­

bustible or non-combustible construction are I" at the
sides and rear, 4" at the front, and 6" from the vent pipe.
Clearance from the top of the jacket is 18" on most mod­
els. Note that a lesser dimension may be allowed on some

models. Refer to the label on the water heater adjacent to
the gas control valve for all clearances.________

ACAUTION

WATER HEATERS EVENTUALLY LEAK: Installation of
the mter heater must be accomplished in such a manner

that if the tank or any connections should leak, the flow of
vrater will not cause damage to the structure. When such

locations cannot be avoided, a suitable drain pan should

be installed under the water heater. Drain pans are avail­
able at your local Sears store. Such a drain pan must be

not greater than I

'A

inches deep, have a minimum length

and width of at least

1

inches greater than the water

heater dimensions and must be piped to an adequate
drain. The pan must not restrict combustion air flow.
Under no circumstances is the manufacturer or Sears to
be held liable for any water damage in connection with
this water heater.

AWARNING

Do not use this appliance if any part of it has been under

water. Immediately call a Sears Service Technician to

inspect the appliance and to replace the gas control or any

part of the burner system which has been under water.

AWARNING

HYDROGEN GAS: Hydrogen gas can be produced in a hot
water system that has not been used for a long period of
time (generally two weeks or more). Hydrogen gas Is
ex^mely flammable and explosive. To prevent the possi­
bility of injury under these conditions, we recommend the

hot water faucet be opened for several minutes at the
kitchen sink before any electrical appliances which are

connected to the hot water system are used (such as a dis­

hwasher or vnishing machine). If hydrogen gas is present,

there will probably be an unusual sound similar to air
escaping through the pipe as the hot water faucet is
opened. There must be no smoking or open flame near
the foucet at the time it is open.

AWARNING

INSULATING JACKETS: When installing an external
water heater insulation jacket on a gas water heater:
• DO NOT cover the temperature-pressure relief valve.
• DO NOT put insulation over any part of the top of the

gas water heater.

• DO NOT put insulation over the gas control valve or gas

control valve/bumer cover, or any access areas to the

burner.

• DO NOT let insulation around the gas water heater to

get within 8 inches of the floor (air must get to the

burner).

• DO NOT cover or remove operating instructions, and

safety related warning labels and materials affixed to the
water heater.

Failure to heed this will result in the possibility of a fire or