Installation Instructions (cont’d)

2. The convertible element is located behind the lower access

panel of the water heater. Remove the two screws securing
the access panel, and remove panel.

3. Remove the insulation block to expose the opening.

5. Remove the screws from terminal 2 of the element, and move

the looped end of the wire aside.

6. The buss bar is labeled 5500 W. Place the buss bar over termi­

nals 2 and 3 with the 5500 W visible. Install the extra screw
provided into terminal 3.

7. The wire removed from terminal 2 has a looped end. It must

remain looped and now be placed (as shown) on top of the
buss bar, over the opening of terminal 2, and secured using
the remaining screw.

4. Lower Element; Lift out the tab as shown to unclip the

terminal cover from the thermostat. The terminal cover can
now be removed from the thermostat.

8. Tighten terminals 2 and 3 to ensure proper electrical

connection.

AWARNING

Failure to tighten terminal screws can cause a fire which
can resuit in DEATH, SERIOUS BODILY INjURY, OR
PROPERTY DAMAGE.